Detection of Acupuncture Points and Meridians Based on their Electrical Properties: Current Evidence and Future Research Perspectives

1 - The “Carol Davila” University of Medicine and Pharmacy, Bucharest, Romania; argyrisperiferakis@gmail.com (A.P.);

2 - Akadimia of Ancient Greek and Traditional Chinese Medicine, Athens, Greece; kostas.periferakis@gmail.com

3 - Elkyda, Research & Education Centre of Charismatheia, Athens, Greece

4 - Pan-Hellenic Organization of Educational Programs (P.O.E.P.), Athens, Greece

5 - Panait Sirbu Obstetrics and Gynaecology Hospital Bucharest, Bucharest, Romania

6 - Department of Dermatology, Carol Davila University of Medicine and Pharmacy, Bucharest, Romania; daniel.costache@umfcd.ro

Correspondence: argyrisperiferakis@gmail.com (A.P.); kostas.periferakis@gmail.com (K.P.)

DOI: https://doi.org/10.55453/rjmm.2025.128.5.2

Received: 25 May 2025

Revised: 12 July 2025

Accepted: 24 July 2025

Abstract:

Acupuncture is one of the main components of Traditional Chinese Medicine and has been applied as a therapeutical method for centuries. As a therapeutical system, it is based on the use of specific lines in the human body, called meridians, and specific acupuncture points, for choosing the locations where the needles will be applied, depending on the specific problem. In the last few decades, there have been increasing efforts to detect and document the existence of such meridians and points based on at least some of their electrical properties being different when compared to the surrounding skin. A number of researchers have designed experiments, which have had varying degrees of success. Since different researchers have used different experimental setups, and the sample size is usually low, there are issues of validity and comparison between different research results. On the other hand, the majority of available evidence is in favor of there being points and lines characterised by distinct electrical properties, corresponding to acupuncture points and meridians respectively. At the same time, several other theories have been proposed to explain the biological basis of acupuncture points and meridians, while their connection to specific cellular components or neural sequences is an intriguing possibility. While comprehensive research is required to fully document the electrical properties of acupuncture points and meridians, a connection between such properties and their biological basis must also be established.

Keywords:
Citation:

Periferakis A, Periferakis K, Iftime A, Troumpata L, Periferakis AT, Maier C, Costache DO. Detection of Acupuncture Points and Meridians Based on their Electrical Properties: Current Evidence and Future Research Perspectives. R. J. Mil. Med. 2025, 128(5): 378-400; https://doi.org/10.55453/rjmm.2025.128.5.2

Article content:

INTRODUCTION

Acupuncture is an integrative part of Traditional Chinese Medicine, and has been practised in China [1] and Japan and also in Korea [2, 3] for centuries. It is certain that acupuncture appeared in China although it is difficult to trace its exact historical era of emergence [4]; much later it would be disseminated in Japan, during the 5th century AD [5]. The practises of acupuncture would later become known to Europe by the end of the 17th century, through the works of Willem Ten Rhijne and Engelbert Kaempfer [6]. Following a hiatus of almost a century, after 1850, it would be again be advocated fervently by George Soulié de Morant in 1940s France, and gradually spread to Europe [7].

In the West, there is an ongoing disagreement regarding the efficacy of acupuncture in particular and of alternative therapies in general, both within and outside of the medical community, despite there being numerous studies which are in favour of acupuncture’s effectiveness [8-16]; iatrogenic complications and side-effects are also very rare [17]. Even veterinary acupuncture has been gaining traction as of late [18-21], although we will not be dealing with that in the present article; notably, research on acupuncture points has already began in earnest since the 1990s [22, 23] – there have even been some reports of the effects of acupuncture in plants [24-29]. It has long been accepted by numerous physicians and researchers that acupuncture can be integrated with modern Western medicine [11,30].

In contrast to the methods of Western medicine, also known as “evidence-based medicine”, the exact definition of acupuncture points and meridians and the associated “flow of qi”, which constitute the principal theory behind acupuncture therapy, is a concept that cannot be quantified and determined accurately by available technical means, at least for now. There are numerous research efforts which have attempted to describe the different electrical properties of acupuncture points.

The different electrical properties of acupuncture points compared to non-acupuncture points in the human body form the basis for the development of special acupuncture point locators, both for somatic and for auricular acupuncture points. It is important to note here that the existence of differences, at some physiological level, between random points and acupuncture points, lends credence to acupuncture being a legitimate therapeutic method more so than mere psychological suggestion [31] or some type of a placebo effect. A research by Vickland et al. [32] suggested that acupuncture changes the electrical properties of the acupuncture points themselves. Even so, the general difficulty in obtaining consistent and reproducible readings in certain points in the skin and the absence of any known physiological mechanism does not allow for a definite determination of the electrical characteristics of acupuncture points [33]. Recently, the advances in machine learning and artificial intelligence [34-39] may allow for different approaches and yield more conclusive results, although nothing definitive is available as of yet. It is possible that a part of the difficulties in establishing a clear-cut model for detecting TCM meridians and acupuncture points has to do with the biological structure of the skin.

The human skin comprises four successive layers, from the exterior to the interior: stratum corneum, living epidermis, dermis, and hypodermis. Detailed investigations into the structure and specific properties of the skin have been made by a number of authors [40-42]. Each of these layers has different conductive, capacitive and dielectric properties; predominantly these depend on the applied voltage although both age [43] and the relative health condition affect them [44]. In essence, parameters such as resistance, impedance and capacitance are a reflexion of the physical properties of the skin [45].

There exist a number of studies, detailing the different skin dielectric properties, depending on the applied voltage, at different frequencies, both for the entirety of the skin layer [46] and for each layer in particular [47-49]. In general, the living epidermis has higher resistivity than the dermis, while the resistivity of the dermis is not as variable. The higher the number of available ions the lower the resistivity values [50]; since the dermis is more hydrated it is reasonable that it has a higher ion content and therefore a lower resistivity [51]. The main component of impedance is the stratum corneum, the most hydrophobic of the skin layers [45]. Another important factor is the relevant permittivity, which reflects the amount of bound charge displacement or polarisation, in a given area, under the influence of an applied electric field [52]. This property is frequency-dependent and is influenced by the existing conditions at a cellular and molecular level [53-55].

In this review, we will present the most important research regarding the determination of acupuncture points and meridians, mostly based on the measurements of electrical parameters, in an effort to interpret their different and sometimes contradictory results. We will also try to interpret these results in the context of the general biological properties of the skin and underlying tissues. As it will become evident, there are a multitude of different studies and methods and we allude to as many of them as reasonably possible, but we have chosen to present in tables only those researches which have focused in measuring electrical properties using electrodes, as this is the focus of our paper. Finally, we will offer possible explanations for the observed phenomena, based on recent discoveries, and directions for future research.

TCM MERIDIANS AND RESEARCH ON THEIR EXISTENCE

There are numerous types of meridian groups, but here, for research purposes we will focus on the 12 principal meridians and the 2 most important extraordinary meridians (Table 1) – to our knowledge no research on locating any other type of meridian, such as collateral or connecting meridians, has been performed using modern methods.

As limb localisation, based on TCM, we define the limb on which most of a meridian’s points can be located; most often it also contains the point of origin of the meridian. The time of maximum activity for each meridian indicates when its most active for therapy, and may correspond to the modern concept of circadian rhythms, which has been discussed in many clinical contexts [59-62].

The 12 principal meridians are associated with organs of the human body, although the properties of these organs do not always correspond to those attributed to them by Western Medicine, and medical acupuncture research. For example, in TCM, the Pericardium Meridian corresponds to the ‟organ” of pericardium, which is however recognised only as an anatomical structure surrounding the heart, and not an organ proper [63,64]. Moreover, Du Mai and Ren Mai do not correspond to any organ but are associated with the regulation of other processes and functions [65,66].

In another example, the Lung meridian is associated with skin health in TCM, a seemingly paradoxical connection by Western medicine standards; however, according to a number of studies, pulmonary pathologies have skin-related manifestations, as is the case, for example of chronic obstructive pulmonary disease [67,68], and of recurring pulmonary capillaritis [69]. In a reverse example, some

skin disorders in children have pulmonary manifestations [70]. While these remarks are interesting and point to a corroboration of many of the principal tenets of TCM, the mainstay of research on verifying the existence of meridians is concerned with identifying them based on their different electrical properties.

Table 1: Principal TCM meridians and their principal characteristics (based on Soulié de Morant [56], Liangyue et al. [57], Tilikidis [58], and Periferakis [6]).
Western Meridian Name Chinese Meridian Name Limb Localisation Point of Origin Acupuncture Points in Meridian Time of Maximum Activity
Lung Taiyin Hand Upper lateral chest, approximately at the level of the 1st intercostal space 11 0300-0500
Large intestine Yangming Hand Radial end of the distal phalanx of the index finger, near the corner of the nail 20 0500-0700
Stomach Yangming Foot Under the eye, directly on the line traversing the pupil, between the eyeball itself and the infraorbital ridge 45 0700-0900
Spleen Taiyin Foot Medial side of the big toe, near the corner of the nail 21 0900-1100
Heart Shaoyin Hand Apex of the axillary fossa 9 1100-1300
Small Intestine Taiyang Hand Ulnar side of the distal phalanx of the little finger, near the corner of the nail 19 1300-1500
Urinary Bladder Taiyang Foot Near the eye in the depression near the inner canthus 67 1500-1700
Kidney Shaoyin Foot Sole of the foot, in the depression former with the foot in plantar flexion 27 1700-1900
Pericardium Jueyin Hand In the 4th intercostal space, by the nipple laterally 9 1900-2100
Triple Boiler Shaoyang Hand Ulnar side of the distal phalanx of the ring finger near the corner of the nail 23 2100-2300
Gall Bladder Shaoyang Foot Lateral to the outer canthus, on the lateral side of the orbit 44 2300-0100
Liver Jueyin Foot Lateral side of the big toe near the corner of the nail 14 0100-0300
Governor Vessel Du Mai Under the tip of the coccyx 28
Conception Vessel Ren Mai Perineum 24

Previous studies on the identification of meridians based on their electrical properties

In general, and compared to the studies on individual acupuncture points, which will be presented on the next section, meridian studies are characterised by a larger sample size and are thus of a higher statistical significance. A number of different measuring techniques were used, and this raises the issues of the comparability and reproducibility of results (Table 2). Probably the earliest research on the different electrical properties of meridians was conducted by Nakatani [71], in the 1950s.

The research of Reichmanis et al. [72] calculated electrical parameters between two different acupuncture points of the same meridian, and determined, using Laplace analysis, that the electrical resistance values were lower. Between the line connecting the two acupuncture points studied, the 14th and 12th of the Large Intestine meridian, there was no other acupuncture point, which could potentially alter the measurements. In the same year, the same authors used the same experimental setup to calculate electrical resistance between the 3th and the 4th acupuncture point of the Heart meridian, with similar positive results [73].

The research of Reichmanis et al. [74] this time measured the resistance between two non-acupuncture points on the Heart meridian; again skin impedance was significantly lower, compared to the control area. This indicates that the presence or absence of acupuncture points in a given meridian area does not affect the clearly different electrical properties of the meridians.

The study of Ogata et al. [75], while not focused on finding the location of meridians based on their electrical properties – indeed it took for granted that the meridians are located on the trajectories described by Traditional Chinese Medicine – detected that there were significant differences in the electrical resistance values of meridians during the different stages of general anaesthesia. We consider the fact that all 12 of the studied meridians had such variations is an, at least indirect, corroboration of meridian location based on different electrical properties, and this is why we included this research. Moreover, we have also included this research in the acupuncture points section of this paper, given that the meridian resistance values were calculated as averages from a number of distinct points in each meridian. Similar results, albeit of a lesser magnitude, were noticed by Ogata et al. [76] in patients under local anaesthesia. Due to the smaller extend of the electrical resistance fluctuation we classify the findings of this research as ambiguous.

It is important to note that the electrical parameters of the skin during post-surgical resuscitation are known to vary, based on the research of Bubnova et al. [77], but it is uncertain if this phenomenon has any bearing on the two aforementioned researches.

Following electrical stimulation at the Jing point of the Stomach (45th of the meridian), 98% of the patients, from a sample of 51 patients tested in an acupuncture clinic, were found to exhibit altered impedance values across the Stomach meridian [78]. The research of Hu et al. [79], which used a larger sample, compared to most of the research efforts examined in this paper, determined that the majority of low impedance points, in the areas examined, where found within a distance of less than 5 mm from acupuncture meridians. Interestingly, they performed this test for all 14 main meridians. A year later, Hu et al. [80] used an electrode moving at an even velocity over the forearm, and computer plotting to demonstrated that most of the detected low skin impedance points were located within the traditional courses of TCM meridians. Similar results were produced by Huang et al. [81], although few details exist on their experiments.

During the research of Zhang et al. [82], impedance was found to be lower in meridians, compared to other skin regions, and to change during needling, a process potentially associated with interstitial fluid fluctuation caused by neuronal reflexes. The research of Martinsen et al. [83], performed using a sample of 20 healthy subjects, did not discover any low resistance trajectories on the volar aspect of the forearm. However, the accuracy of the measuring method of this research has come into question [84]. A subsequent research by Johng et al. [85] yielded positive results, while the research of Ahn et al. [86] had ambiguous findings, in that it demonstrated that the impedance along the Pericardium meridian was decreased, but this was not the case for the Spleen meridian.

The research of Spaulding & Chamberlin [87], who performed acupuncture in order to measure the conductivity across the Large Intestine meridian, yielded statistically significant differences in favour of the meridian, but these were not pronounced enough; thus, we regard these results as being ambiguous.

Table 2: Basic characteristics and outcomes of research of the location of meridians based on their electrical properties
Authors & Reference Year of Study Sample Size Healthy Individuals Control Current Used Experimental Setup Results Evaluation
Reichmanis et al. (73) 1977 10 Yes 1-1.5 cm parallel lines medially and parallelly DC, 1 V 1 cm carbon-impregnated conducting rubber electrodes (modified LIDC electrodes by Ritter Co.) The electrical resistance values in the line connecting the two acupuncture points were lower compared to the control Positive
Reichmanis et al. (72) 1977 10 Yes 1-1.5 cm parallel lines medially and parallelly DC, 1 V 1 cm carbon-impregnated conducting rubber electrodes (modified LIDC electrodes by Ritter Co.) The electrical resistance values in the line connecting the two acupuncture points were lower compared to the control Positive
Reichmanis et al. (74) 1979 10 Yes 1.5 cm parallel lines medially and parallelly DC, 1 V 1 cm carbon-impregnated conducting rubber electrodes (modified LIDC electrodes by Ritter Co.) The electrical resistance values in the line connecting the two non-acupuncture points were lower compared to the control Positive
Ogata et al. (75) 1983 10 No None AC* Standard ECG electrodes taped over the chosen acupuncture points in each meridian; values measured during various intervals from preanaesthesia to postanaesthesia There was a decrease of up to 36 % in skin resistance in 10 of the 12 studied meridians, and by a maximum of 100 % and 73 % on the kidney and bladder meridians respectively Positive
Ogata et al. (76) 1983 6 No None AC* Standard ECG electrodes taped over the chosen acupuncture points in each meridian; the values were measured before and after the application of local anaesthesia There were fluctuations of a rather small scale in all of the meridians studied Ambiguous
Xiang et al. (78) 1984 51 No None AC, 0-100 V Stimulation of the Stomach Jing point using a bipolar electrode and measurements based on the process of Zhu et al. (88) A distinctly localised meridian line for the Stomach was located in the overwhelming majority of subjects after the initial stimulation Positive
Hu et al. (79) 1992 68 Yes Areas laterally removed from the meridians DC, 0-50 V 1 mm pure Ag tip electrode The majority of the studied points within less than 5 mm from all 14 main meridians was found to have low impedance Positive
Hu et al. (80) 1993 12 Yes Areas not belonging to established meridians AC Exploratory electrode moving at a standard velocity over the forearm – computer system used for plotting Low skin impedance points (LSIPs) were discovered and were generally distributed along known meridian courses Positive
Huang et al. (81) 1993 25 Yes Areas not belonging to established meridians AC n/a (perhaps similar to the setup of Hu et al. (80)) Low skin impedance points (LSIPs) were discovered to lie mostly within or very near to known meridian courses Positive
Zhang et al. (82) 1999 12 Yes Non-acupuncture points in surrounding skin AC 4 electrode technique – 4 mm diameter pipes with saline cotton There was a decrease in impedance in the meridian area studied, which fluctuated during needling Positive
Martinsen et al. (83) 2001 20 Yes None AC 16 electrode (0.5 mm diameter) linear array No linear low resistance trajectories were detected Negative
Johng et al. (85) 2002 30 Yes Lateral parallel control at a distance of 6-7 cm from the tested meridian AC 4 electrode technique similar to that of Zhang et al. (82) Higher capacitive effects at acupuncture meridians, compared to the control Positive
Ahn et al. (86) 2005 23 Yes Control segments 0.8 cm distant, medially and parallelly to the tested meridians AC 4 electrode method (0.25 mm Au plated needles serving as the electrodes) supplemented by ultrasound imaging of the connective tissue planes along the tested meridians While impedance in the case of the Pericardium meridians was indeed lower, the same cannot be said for the impedance of the Spleen meridian Ambiguous
Spaulding & Chamberlin (87) 2011 20 Yes Non-meridian tissue AC A test configuration involving a data acquisition hardware, while processing was performed in Matlab; acupuncture was performed during the measurement There is a somewhat better conduction along the Large Intestine meridian, compared to non-meridian tissue; while there is a statistical significance of the values, these are not dramatic Ambiguous

* For these researches the exact data on the type of current used are not available; therefore, based on their use of ECG electrodes and apparatuses we have assumed that it is AC current (this being the more common modality in such machines)

† Similarly, no data on the current type were mentioned and we have assumed it to be AC, which is the most common setting

The particular research parameters of the aforementioned studies on meridian locations are presented in the table below (Table 3).

As can be seen, meridian studies have a higher mean sample size, compared to the acupuncture point studies, which will be presented in the following chapter. In general, there is a greater homogeneity of in research methods and subject selection compared to the following studies on acupuncture points presented in the next section.

The studies with control have also used healthy subjects and there is about an equal number which used AC and DC; most of them have results which can be evaluated as “successful’’. The fewer and more diverse studies with no control have also had a relatively

positive total outcome. Of course, it is easier to locate meridians compared to acupuncture points, as acupuncture point location is a more difficult and precise process.

In the next subsection, a number of studies on locating meridians using other methods were presented. The association between meridians and interstitial fluid has also been explored by a number of authors along with a number of other proposed alternatives

Table 3: Data on the presented research on meridians
Study Type N Mean Sample Size Subjects’ Health Type of Current Used Reported Outcome
Healthy Not Healthy Mixed AC DC Both Positive Ambig. Negative
Studies with control 10 22.00 10 (100%) 0 (0%) 0 (0%) 6 (60%) 4 (40%) 0 (0%) 8 (80%) 2 (20%) 0 (0%)
Studies with no control 4 21.75 2 (50%) 2 (50%) 0 (0%) 4 (100%) 0 (0%) 0 (0%) 2 (50%) 1 (25%) 1 (25%)
Total studies number 14 21.90 12 (85.7%) 2 (14.3%) 0 (0%) 10 (71.4%) 4 (28.6%) 0 (0%) 10 (71.4%) 3 (21.4%) 1 (7.2%)

For example, Li & Zhao [89] proposed that meridians may coincide with the courses of some blood vessels, while Zhu [90] proposed that the meridians as explained by the TCM are, in fact, an erroneous representation of the nervous system. Several hypotheses were proposed by Zhang [91] while the current research consensus focuses on the meridians representing low hydraulic resistance channels associated with the movement of interstitial fluid and specific metabolites [92]. The association of meridians with stem cells was also proposed by Pawitan [93]; bearing in mind that the stem cell potential varies with a number of factors [94-100], this could have a bearing on the differences in meridian studies across individuals.

Other Studies and Theories on the Properties and Location of Meridians

Apart from the more traditional method of detecting and/or identifying meridians based solely on their different electrical properties, a number of authors have tried a variety of different approaches (Table 2). The most probable explanation is that the different electrical properties of meridians are based on a neural electrical field [101].

The tentative research of Jiang et al. [102] indicates that along meridians, the microcirculatory response to moxibustion therapy is different; thus it may be inferred that there may be well be some level of difference in the microvasculature of meridians, compared to other locations on the body. Research suggests that, in rat experiments, moxibustion therapy seems to modulate gene expression [103]. A clinical trial protocol on the same principle was proposed by Hu et al. [104]. On a different note, the research of Lin et al. [105], indicated that the electrical flow across meridians changes depending on acupuncture needle manipulation during therapy.

Crucially, as is also the case for certain acupuncture points, the electrical properties across meridians seem to differ between pathological and healthy conditions [106,107]. On a related note, a potential association between electrical resistance changes and pain after orthopaedic surgery, which however warrants further investigation, was proposed by Rezvani et al. [108].

The most currently prominent avenue of research on defining the morphofunctional characteristics of meridians centres on them being supposedly channels where a higher amount of interstitial fluid is found. A gel model based on this concept seems to suggest that there is some merit in this theory [91]. An earlier research by Zhang et al. [109] in rats, had not produced any corroborating results.

Finally, the different electrical properties of meridians may be associated by an ion drift theory, as proposed by Liu et al. [110]; notably the research of Lee et al. [111] also mentioned that the special properties of acupuncture points may be associated with different ion concentrations.

VARIATION OF SKIN ELECTRICAL PROPERTIES AT ACUPUNCTURE POINTS

The classical Chinese theory postulates that there exist over 300 acupuncture points, distributed across the 12 principal and 2 extraordinary meridians mentioned above, all over the human body.

The stimulation of these points, based on the view of traditional acupuncturists, adjusts the “qi flow” along the human body; the most frequent proposed interpretation for this notion of “qi energy” is electrical energy [112] and this has been the focus of the majority of meridian detection-associated research.

Electrical properties of acupuncture points – Research history

While, based on the traditional theory, the location of points is determined based on the anatomical parameters and locations of the human body, it was though also possible that these points exhibit distinct electrical properties; based on this speculation, relevant research was performed in the 1950s ([33,113]; and references therein), documenting that at least some acupuncture points where characterised by specific electrical properties.

Table 4: Basic characteristics and outcomes of research of the location of acupuncture points based on their electrical properties
Authors & Reference Year of Study Sample Size Healthy Individuals Control Current Used Experimental Setup Results Evaluation
Reichmanis et al.(122) 1975 7 Yes Anatomically similar location within 1 cm2 DC, 8 V 1.5 mm measuring electrode and a specially designed wheel electrode; both made from stainless steel Most of the acupuncture points measured were identified based on their electrical parameters in all subjects Positive
Reichmanis et al.(123) 1976 10 Yes Suitable nearby anatomical location DC, 2 V 36 stainless steel rods in a grid pattern over the acupuncture point Over 75% of the acupuncture points were electrically different compared to the control areas Positive
Hyvärinen & Karlsson (124) 1977 5 Yes Surrounding skin DC, 6.7 V 0.5 mm circular electrode and 2.5 mm reference electrode Points of consistently low electrical resistance, resembling acupuncture points, were identified Positive
5 Yes DC & AC 0.5 mm silver wire Massively lower, about 50-100 times, electrical resistance was identified in the same points as above Positive
McCarroll & Rowley (125) 1979 8 Yes None AC (V is a measured variable) 5 x 5 grid with the acupoint in the centre The decreased electrical impedance detected at a few points was attributed to temporal variations and the pressure of the probe on the stratum corneum Negative
Poon et al. (127) 1980 9 Yes Surrounding skin AC, 0-18 V Special epiductive tape electrode Numerous spots of increased conductance were identified, many lying across the meridians, but a lot differing significantly from conventional acupuncture locations Ambiguous
Jakoubek & Rohlícek (129) 1982 n/a n/a n/a DC & AC Multiple electrodes Many points with increased electrical conductance, corresponding to acupuncture points, were detected Positive
Ogata et al. (75) 1983 10 No None AC Standard ECG electrodes taped over the chosen acupuncture points in each meridian; results measured during various intervals from preanaesthesia to postanaesthesia There were marked electrical resistance variations during the different stages of anaesthesia, in most of the acupuncture points studied Positive
Ogata et al. (76) 1983 6 No None AC Standard ECG electrodes taped over the chosen acupuncture points in each meridian; the values were measured before and after the application of local anaesthesia There were fluctuations of a rather small scale in all of the individual points measured Ambiguous
Margolin et al. (131) 1996 34 No Auricular control zones not comprising any acupuncture points DC Specially developed device with a 1 mm Ag/AgCl electrode composition; use of biogel as a conducting medium – the measurements were performed using auricular acupuncture points; subsequent acupuncture of both control and active points was performed The therapeutic effects of acupuncture in low impedance points were not very much different from the effects on non-acupuncture points Ambiguous
Zhang et al. (82) 1999 12 Yes Non-acupuncture points in surrounding skin AC 4 electrode technique – 4 mm diameter pipes with saline cotton There was a decrease in impedance in the meridian area studied, which fluctuated during needling Positive
Falk et al. (130) 2000 34 No Control zones on the helix of the ear AC An Ag/AgCl probe of 1 mm diameter in a 2 x 2 grid The sites of lowest impedance were identified as being within active zones Positive
Zhang et al. (138) 2004 12 Yes Two points on either side of the low impedance points at a distance of 0.5 cm AC Four-electrode impedance instrument (Korean SPAC instrument) based on the methodology described by Zhang et al. (82) It was found that 71 % of the acupuncture points tested had a lower impedance compared to the control points Positive
Lee et al. (139) 2005 20 Yes One non-acupuncture point DC, 1.28 V Electrodes affixed to two acupuncture points and one non-acupuncture point; constant pressure applied in the 4th point of the Large Intestine Meridian Meridian points exhibit a greater conductivity compared to non-meridian points Positive
Pearson et al. (141) 2007 20 Yes Nearby control sites no more than 5 cm away from the acupuncture points DC & AC Prognos instrument (4.57 mm probe tip) along with a specially designed PT probe None of the acupuncture points measured exhibited lower impedance values compared to the control points Negative
Kramer et al. (142) 2008 43 Yes Surrounding skin DC, 4.8 V (mean) Specially designed array comprising 64 electrodes covering an area of 36 cm2 Only about 1/3 of the measured acupuncture points exhibited significantly decreased electrical resistance values Negative
Kramer et al. (143) 2009 53 Yes Surrounding skin DC, 4.8 V (mean) Specially designed array comprising 64 electrodes covering an area of 36 cm2 Some acupuncture points displayed elevated and some reduced impedance values compared to the surrounding areas; it is therefore considered possible that acupuncture points possess different transient electrical properties compared to the surrounding skin Ambiguous
Rezaei et al. (144) 2012 18 Yes Parallel series of four control needles placed 0.8 cm medial to the meridian needles AC 4 electrode technique specifically designed for the study in question The point studied (PC4) was found to be electrically distinct from other non-meridian points and similar to other points of the same meridian Positive
Wong (145) 2014 65 Yes A neighbouring non-acupuncture point, 2 cm distant DC, 0.5 V Bipolar electrode (3 mm in-between electrodes) and a sensing probe The point studied (LI14) was not found to be electrically distinct from the control point Negative

* For these researches the exact data on the type of current used are not available; therefore, based on their use of ECG electrodes and apparatuses we have assumed that it is AC current (this being the more common modality in such machines) † Similarly, no data on the current type were mentioned and we have assumed it to be AC, which is the most common setting

Some decades earlier, in the 19th century, August Weihe (1840-1896), a medical doctor and homeopathy practitioner came to the conclusion that specific points in the human body were found to be more painful compared to the others, following the ingestion of a toxic quantity of certain homeopathic remedies [114]; it has been mentioned that Weihe knew the notion of specific therapeutic points from a relative in China [115]. It is also notable that Soulié de Morant mentioned that these points coincided with Chinese acupuncture points [116]. The theory of homeosiniatry was proposed by Roger de la Fuye (1890-1961), in 1932, to account for the physiological similarities between homeopathic remedies and acupuncture points; notably, he impregnated some acupuncture needles with homeopathic remedies in a number of his acupuncture therapies [116]. Today, both Weihe and de la Fuye are considered as the ancestors of the theory of electroacupuncture [117]. In 1953, probably the first electroacupuncture apparatus was designed and built by R. Voll (1909-1989) and F. Werner [113].

Despite many studies having taken place on this subject (Table 4), some of them are deemed as being of poor quality, due to a number of factors [118]. A particular point in researching the electrical properties of acupuncture points is the standard to which the data obtained are compared with; more precisely, while acupuncture points may not present minimal electrical resistance at an absolute level, the issue is if they exhibit a different electrical resistance compared to their surrounding tissues. Dedicated research to for the particular, if any, electrical properties of acupuncture points began in the 1970s; notable research efforts from this era are those of Frost & Orkin [119] and Kaslow [120]. Contemporary views on the existence and function of acupuncture points in particular and acupuncture in general can be found in McCarroll [121].

The research of Reichmanis et al. [122] was based on the principle that acupuncture points exhibit a reduced electrical resistance [30]; accordingly, they aimed to prove that acupuncture points exhibited a distinct resistance minimum compared to the surrounding tissue. They employed direct current and used some of the most easily accessible points of the Large Intestine (LI) and Pericardium (Per) meridians; they concluded that all of the studied points exhibited an increased electrical conductance, relevant to the surrounding tissues and most could be located in the majority of subjects. In a subsequent research [123], using a 36 rod grid, on skin disinfected with 90 % alcohol and moistened with tap water, over selected acupuncture loci; suitable control areas were also selected. The points selected were again easily accessible, from the Triple Boiler (TB) and Lung (Lu) meridians. Most, but not all, points were detectable based on different electrical parameters. Further promising results were obtained by Hyvärinen & Karlsson [124], who detected a number of low electrical resistance points on the forearm, hands and ears, which resembled acupuncture points, albeit in a small sample of five healthy individuals. Similarly, in these points the electrical impedance values were found to be massively lower compared to the surrounding skin [124].

Despite these positive results, McCarroll & Rowley [125], who measured the electrical conductance in certain acupuncture points in the hands and arms, came to an unfavourable conclusion. It is noteworthy that this study considered extensively the probable consequences of the pressure applied by the electrode on the skin, to the measurements; in addition, it considered whether any break in the stratum corneum may influence the results. The authors mentioned that, based on their measurements, the time-dependent nature of skin conductance, as asserted by Geddes & Valentinuzzi [126], applied to their measurements as well. They concluded that any detected variations were the result of differing electrode pressure on the stratum corneum and the temporal variability of skin conductance [125].

In an effort to minimise the effect of the electrode itself, Poon et al. (127) used a special epiductive tape electrode, based on the method of Burton & Maurer (128). They determined that a number of points which had different electrical properties corresponded with acupuncture points, but other such points did not; moreover, no statistical analysis demonstrated that across all subjects no significant coincidence between electrically ‟special” points and acupuncture points was revealed. Even more strikingly, the points of good conductance differed between the two arms of the same subject (127). In addition, a number of low resistance points coinciding with acupuncture points were detected in both humans and rats, and also some such points – not corresponding to acupuncture points – were found in areas of referred pain (129). The research of Ogata et al. (75), to which we have already referred to in the meridians section, also noted that electrical properties of acupuncture points changed during different stages of anaesthesia. For the same reason, the other research of Ogata et al. (76) is included in this chapter too.

A four-electrode method was employed by Zhang et al. (82) to evaluate a single acupuncture point, the 3rd of the Pericardium meridian, during, before and after needling, compared to a number of control points. It was noted that electrical impedance changed in all points, but the impedance reduction in acupuncture points was greater; it was theorised by the researchers that the impedance decrease was owed to a transient increase of interstitial fluid during needling, which is most probably associated with an axonal reflex and/or blood capillary expansion (82). We have already included this research in the section on meridians, but we also place it here because of its focus on the area around a single point.

Meanwhile, Falk et al. (130), using as test subjects patients under treatment for cocaine addiction, detected significantly lower impedance values in the active zones of the ear, i.e. those corresponding to auricular acupuncture points. A similar research had already been conducted by Margolin et al. (131), who tested the differential efficacy of acupuncture treatment in high and low impedance points in the ear; the results in this clinical trial had been ambiguous, in that while needling in low impedance points – corresponding to acupuncture points – had somewhat better effects, this difference was assessed as not being significant enough. Again, this therapeutic approach concerned auricular acupuncture in cocaine addicts. Interestingly, during auricular acupuncture it proved impossible for the subjects to identify, based on pain perception, when acupuncture points were needled, or when needle placement was random (132). Incidentally, there is as of yet no consensus regarding the efficacy of auricular acupuncture in treating cocaine addiction; the results range from mildly encouraging (133, 134) to inconclusive (135, 136) or even negative (137).

Using the four-electrode method, Zhang et al. (138) determined that in their research on a small number of heathy subjects, 71 % of the acupuncture points had a significantly lower impedance compared to the control points on either side. The research of Lee et al. (139) suggested that between two acupuncture points the conductance was greater than between a non-acupuncture and an acupuncture point. Since the second pathway did not belong to an established meridian, they concluded that their experiment perhaps corroborated the theory of Chen (140), who proposed that the dielectric constant along meridians is lower compared to other non-meridian trajectories. Contrary to this, the research of Pearson et al. (141), which was one of the most well-controlled studies, did not detect any significant differences in electrical impedance between acupuncture and non-acupuncture sites.

The research of Kramer et al. (142), who studied the variations of electrical skin resistance in the 34th point of the Gall Bladder meridian in 43 healthy volunteers concluded that, compared to the surrounding skin, only about 33% of the studied points exhibited statistically significant differences; they rightly considered such a small percentage to not be in agreement with most other performed research. A subsequent clinical trial (143) yielded ambiguous results.

The research of Rezaei et al. (144) aimed to determine if a certain acupuncture point, the 4th of the Pericardium meridian, had any different properties compared to its surrounding ones and other points in the same meridian; it was found that it was electrically distinct compared to non-meridian points, but not so much compared to meridian ones. The four-electrode method employed was based on the research of Zhang et al. (82).

The research of Wong (145) is particularly important, as it strived to do stringent lab-controlled measurement of skin resistance of an acupuncture point (14th point of Large Intestine Meridian) on a larger sample (65 participants) than other studies. In their larger sample, they found no statistically significant difference in the electrical resistance between acupuncture and non-acupuncture points.

The results from all the studies in Table 4 are presented in the following table (Table 5), in order to enable a more complete view of the current research consensus.

Table 5: Data on the presented research on acupuncture points
Study Type N Mean Sample Size Subjects’ Health Type of Current Used Reported Outcome
Healthy Not Healthy Mixed AC DC Both Positive Ambig. Negative
Studies with control 15 23.1 13 (86.7%) 2 (13.3%) 0 (0%) 5 (33.4%) 8 (53.3%) 2 (13.3%) 9 (60%) 3 (20%) 3 (20%)
Studies with no control 3 8 1 (33%) 2 (66%) 0 (0%) 3 (100%) 0 (0%) 0 (0%) 1 (33%) 1 (33%) 1 (33%)
Total studies number 18 20.6 14 (77.8%) 4 (21.2%) 0 (0%) 8 (44.5%) 8 (44.5%) 2 (11%) 10 (55.6%) 4 (22.2%) 4 (22.2%)

As it can be easily seen from the aforementioned concise table on research results, the studies with control have a considerably larger sample size compared to the studies with no control, where its absence along with the limited sample size further undermines their statistical significance.

In assessing the more significant first group of studies, the overwhelming majority used healthy subjects, while half of them used direct current. Only a small percentage were negative, while the majority was positive or ambiguous. The results were equally distributed in the second group of studies; overall, about half of the studies presented in this section were unambiguously positive, although we would suggest that this statistic has been negatively skewed due to results from the studies with no controls. The majority of studies selected healthy subjects only, while the most frequent current used was alternating current by a small margin, followed by direct current; very few studies opted for both currents.

The relative discrepancy in results can be partly, in our opinion, explained by the fact that the majority of studies have limited their measurements in the upper limbs. The most recent research indicates that acupuncture point resistance values are non-linear [146] and this may influence the results, because on one hand some researches may have focused in non-optimal areas, and on the other few data on the lower parts of the body, and the head exist, if any at all. It is, however, a fact that electrical resistance measurements exhibit great variations depending on anatomical locations [118].

A curious phenomenon, termed the “drift” effect, was discovered by Mayer-Gindner et al. [147], where, if alternating current (AC) is used by the electrode, in the same point, gradually the electrode-skin resistance will decrease. They proposed that at least 20-30 min, if not 40-50 min should pass between two consecutive measurements, even if the point measured is not the same but an adjacent one. They suggested a new method for locating acupuncture points using alternating current. However, this does not seem to be the case, at least to our knowledge, as 5 out of 6 control-group AC studies yielded a positive result.

Presumably, the same influence of the circadian rhythm on meridians, if confirmed, should apply also to acupuncture point measurements. It is known for certain that the circadian rhythm affects skin physiology [148]. The circadian rhythms are also known to affect skin hydration [149], a factor which for sure influences the electrical resistance of the skin and potentially the detectability of acupuncture points.

In addition, there are evidence which suggest that the partial oxygen pressure values in the tissues underlying the meridians are higher than the tissues under random anatomical sites [150]. We mention this research here, instead of the previous meridian chapter, since it was performed on acupuncture points but in essence concerns the whole meridians trajectories. The extensive scientific literature in matters other than electrical properties per se, as outlined in the previous section, seems to corroborate the existence of acupuncture points as distinct morphofunctional entities.

We may conclude that regardless of whether the loci of low electrical resistance can be considered as being the same as the acupuncture points of TCM or not, it is by far more probable that such distinct loci do exist. Their diameter ranges from 1 mm to about 4 mm [120,151,152]. A factor which complicates matters is the relative uncertainty in locating acupuncture points [153], as based on textbooks there may be slight variations [154]; taking into account the tiny diameter of the loci of decreased resistance, it is conceivable that some negative research outcomes were influenced by a slightly erroneous choice of measurement sites. Research on whether needling of the exact location is necessary for a successful treatment outcome is still ongoing [155]; perhaps a general location with a diameter of some mm with the locus of minimum impedance at the centre may be considered as an acupuncture point. What is more certain is that the stimulation of acupuncture points, or of areas around them at least, is by far more effective that the stimulation of random, non-acupuncture points, based on a number of studies [156-160].

Other studies and theories on the properties of acupuncture points

There are a number of other studies, which are associated with the particular properties of acupuncture points, but which do not adhere to the pattern thus described, i.e., the comparison between acupuncture and non-acupuncture points in terms of their electrical properties. The effort of morphologically defining acupuncture points has begun since the late 1970s [161] and it is still an ongoing field of research, where many suggestions and research results must be taken into account. From a structural standpoint, it has been proposed that the microvasculature is capable of providing a larger blood supply in acupuncture points [162].

For example, Liang et al. [163] have asserted that the NO (nitric oxide) concentration in the skin, in acupuncture points, is higher compared to non-meridian and non-acupuncture points. According to their experiment, a NO-noradrenaline system is associated with the different electrical resistance at acupuncture points. Their experiment was based on the previous findings of Chen & Ma [164]. In the same year, Ma [165] asserted that, in addition to the NO-noradrenaline system, the reduction of nitrates by bacteria at acupuncture points was also contributing to the different electrical properties. Other relevant studies, with quite favourable results also exist [166-169].

Α limited research effort by Khorsand et al. [170] used an entirely different setup, in that it evaluated the changes of electrical properties of acupuncture points before and after acupuncture was performed – none were detected. A study by Turner et al. [171] aimed to ascertain whether, between arthritis patients which experienced pain and pain-free arthritis patients, there would be any difference between the electrical properties of certain acupuncture points. They concluded that patients which felt pain had different resistance values at acupuncture points, and ventured to suggest that the different electrical energy flow in these patients might be seen as a connection between Western and Chinese medicine concepts.

Ambiguous results, regarding menstrual pain, were yielded by She et al. [172]; the authors do remark, however, that it is a promising field for further investigation. Indeed, following a recent thermographic analysis, Xisheng et al. [173] suggested that a number of acupuncture points is sensitised in patients with primary dysmenorrhea. Interestingly, based on Xu et al. [174], the electrical resistance of specific acupuncture points changes with the variations of blood flow in the uterus, during the menstrual cycle, a result also previously yielded by the research of Wei et al. [175]. At any rate, a nerve-related model to explain acupuncture analgesia was put forward by Silberstein [176]. The values of the electrical properties of a number of acupuncture points were also found to be different in encephaloma patients undergoing surgery [177].

It is also compelling to consider the implications of the research of Weng et al. [178] who suggested that electrical conductance was different between healthy and obese patients, and in fact changed as those obese patients started losing weight.

Recently, an emerging theory suggested that at least some acupuncture points may be thermically distinct between healthy and unhealthy states [179]; this is also a promising field for future research. An earlier review on the subject [180] was more assertive in acupuncture points having a distinct thermal profile, but this is not a unanimously supported conclusion. The infrared profile of acupuncture points may also be of interest in determining the best course of acupuncture therapy [181]. Another study, focusing on asthma patients, suggests that it may be possible to use the values of electrical impedance at certain acupuncture points for screening and treatment effectiveness purposes [182].

The individuality, so to speak, of acupuncture points maybe also be attributable to their differing, compared to the surrounding tissue, ion concentrations, as suggested by the research of Lee et al. [111]. A number of inorganic ions, such as Ca2+ and Mg2+ are distributed prominently on the upper delimitation of the stratum granulosum [183-185], while the distribution of other ions varies in the other layers [184-187]. We might thus suggest, that from a morphological point of view, the distinct acupuncture points represent areas where, for some reasons, there is a differential horizontal and lateral ion distribution across the skin layers. Interestingly, given that the upper stratum corneum is permeable to external substances [188-191], its ionic profile can theoretically be externally modified; thus, by modifying the electrical resistance of acupuncture points it may be possible to modify treatment efficacy.

It must also be noted that, according to the review of Colbert et al. [192], there is an important clinical utility in assessing the variations of electrical properties in acupuncture points, given that they might reveal latent pathologies or be associated with a state of physical exhaustion. The stimulation of acupuncture points with chemical means, also has therapeutical effects as suggested by a number of researchers [193-196]. Regarding this aspect, it is interesting to remark that drug administration in acupuncture sites seems to be more effective compared to non-acupuncture sites [197]. Furthermore, the research of Periferakis & Periferakis [198], in a sample of 40 patients, both healthy and not, using the Pointo Select DT device, for detection of auricular acupuncture points, determined that in the majority of cases, most, but not all points are easily detectable.

An interesting concept is that of neuronal acupuncture [199], which is based on the premise that in acupuncture points, specific neuronal and neuroactive components are stimulated; these loci could comprise the 361 WHO-accepted acupuncture points [200]. The concept of neuronal acupuncture could perhaps be used to explain how or why acupuncture points exhibit different electrical properties, compared to the surrounding skin.

Finally, Cho et al. [201] measured biopotential differences between acupuncture and non-acupuncture points during acupuncture treatment; acupuncture points seemed to have greater variability which seems to be related to the classical concept of the “flow of Qi”. Even the practicing of Qigong, which is theorised to affect Qi circulation, results in significant changes of the electrical potential of acupuncture points [202]. It has also been documented that with needle placement in certain acupuncture points it is possible to observe electrocardiogram and electroencephalogram changes [203,204]; changes where affected during stimulation of nonacupuncture points also, but needle placement in acupuncture points produced more pronounced changes [204].

DISCUSSION

Research on the properties of acupuncture points and meridians has been one of the most prominent topics amongst relevant scholars [205]. It is obvious from the presented studies, that many different researchers have evaluated the identification of acupuncture points based on their electrical parameters, but many of these methods differ significantly, and it is little wonder that their results are not comparable. Of particular interest, however, is the fact that the voltage selected each time seems not to affect the results, i.e., a different voltage will not turn a low impedance point into a high impedance one [206], so at least this offers a modicum of result comparability even if the experimental parameters differ.

Nonetheless, it must be stressed that a host of factors from the parameters of the electrodes, to the physiological and psychological status of the subjects, to the frequencies used, affect the detection of low impedance points [85,207]; therefore, many research results may be rendered inaccurate, and this may also explain the discrepancies in-between the values even of positive-outcome research efforts. Another research by Prokhorov et al. (208) suggest that between racially different populations, the DC measurements of skin resistance are not comparable, a factor which must also be taken into account in future studies. A useful summary of confounding factors in acupuncture point detection research is provided by Luo et al. [209]. It should be noted here that considerable

variations in the localisations of acupuncture points is a fairly common occurrence even amongst experienced acupuncturists [210], i.e., the discrepancies are not limited to apparatus-based location methods.

Current research efforts and their significance

Based on the cumulative research results on both the meridian and acupuncture studies (Table 6) we can see that the majority of them where positive, in that it was possible to identify electrically distinct locations and lines on the surface of the human body. Most of the studies used DC, although an almost equal number used AC, and only 2 used both types of current. Finally, the mean sample size was 21.2 subjects. It is difficult to conclude here what the optimal sample size should be for such a research, as there are quite a number of factors which influence its size [211]; moreover, the statistical significance of a sample does not directly in itself validate the experimental results [212]. However, since meridians and acupuncture points, should, in principle, be detectable in any individual, for this particular type of studies, even a small sample should suffice to determine the outcome. However, as mentioned by Reichmanis et al. [123], not all acupuncture points are detectable at all times, and this may be important for the therapeutic efficacy of acupuncture in different patients, or for different protocols used on the same patient. Anomalies in the detectability of acupuncture points, specifically for auricular acupuncture, have been reported by Periferakis & Periferakis [198].

Table 6: Combined and comparative data on the detection of acupuncture points and meridians based on their electrical properties
Study Type N Mean Sample Size Subjects’ Health Type of Current Used Reported Outcome
Healthy Not Healthy Mixed AC DC Both Positive Ambig. Negative
Studies with control 25 21.9 23 (92%) 2 (8%) 0 (0%) 11 (44%) 12 (48%) 2 (8%) 17 (68%) 5 (20%) 3 (12%)
Studies with no control 7 20.6 3 (42.9%) 4 (57.1%) 0 (0%) 7 (100%) 0 (0%) 0 (0%) 3 (42.8%) 2 (28.6%) 2 (28.6%)
Total studies number 32 21.2 26 (81.3%) 6 (18.7%) 0 (0%) 18 (56.3%) 12 (37.5%) 2 (6.2%) 20 (62.5%) 7 (21.9%) 5 (15.6%)

A number of meridian and point locator devices have entered the market after the 1970s [138]. Given the differences in approaches and the fact that even with complicated experimental setups results cannot always be obtained, it is no wonder that the efficacy of early acupuncture point detectors, based on the properties of the points themselves, was called into question [213]. Newer and more sophisticated devices and sensor arrays, such as those proposed by a number of authors [214-216] may improve detection results and eliminate ambiguity.

Regarding research purposes, the delayed luminescence method [217] and the low energy laser (LEL) coherent light interaction with skin [218] may be of future use in evaluating the dielectrical properties of acupuncture points. The more modern method of electrodermal mapping may prove even more useful [219]. Indeed, in the recent years measuring reliability seems to have improved considerably [220].

Finally, the variations and importance of electrical resistance will prove useful even in considering the physical composition of the needles themselves; recent evidence suggests that by some specific material treatment methods it is possible to affect electrical resistance and therefore the therapeutic potential of the treatment [65]. At any rate, as discussed elsewhere, the electrosensitivity of acupuncture points may be a useful clinical and treatment marker [221]. Bearing in mind that there are a number of proposed mechanisms for the action of acupuncture [222], there exists a host of potential modifying factors in assessing the function and potential of acupuncture points and meridians.

Potential Future Directions of Research

Regarding attempts at a structural and biological interpretation for the existence of acupuncture points and meridians, there exists a number of recent research attempts regarding evidence on a cellular level. The most recently discussed theory is that telocytes may be the underlying biological bases of meridians. This is a specialised type of interstitial cells [223], with cytoplasmic extensions; such a structural particularity enables the communication with other distant cells [224]. Telocytes have been found to reside in a number of different tissues [225-232]. Although appearing similar to some other specialised cells types, both telocytes themselves and their extensions, the so-called telopodes are structurally different [233]; the telopodes are expressed both in the body and in cell cultures [234]. There are many theories on what their exact function may be [235-238], but as of yet there is no consensus. A detailed investigation into the potential association between telocytes and TCM meridians was performed by Yonghong et al. [239], on tissues of different animals. Indeed, it was proved that there exist both homocellular and heterocellular connection between telocytes and telocytes and other cell types respectively [239]. Since telocytes interconnect smooth muscle cells, glandular cells and cells for

different organs, along with nerves and other structures, this could be the long-elusive network enabling the stimulation of superficial skin structures to have an effect on distant and apparently unrelated morphofunctional units. Notably, as Yonghong et al. [239] assert, the existence of telocytes could be a basis for the interpretation of all the current meridian-associated theories proposed by numerous authors [240-244]. Despite the promising aspects of telocyte research, it must be noted that, as of yet, and to the best of our knowledge, it has proven impossible to interpret all the physiological and pathological connections mentioned in TCM using the notion of telocytes. This of course might be traced down to the fact that telocytes are dynamic cells, so that static imaging techniques may not be always able to trace the full extent of their network. Alternatively, there might be telocytes that are sometimes overlooked in research for a number of reasons [245]. Or, apart from the two aforementioned constraints, it may just so happen that telocytes are not the only answer to this conundrum. Interestingly, a telocyte-based mechanism for the cure of ulcerative colitis by acupuncture was recently proposed by Bai et al. [246].

Another theory on what is the biological basis for meridians and acupuncture points involves keratinocytes, the most dominant cell type of the epidermis [247]. Regarding their electrical activity, it is known that they possess physiologically, a variety of transient receptor potential channels [248-253], along with a number of other channels and receptors [254, 255]. Based on this aspect, and on the experimental research of Denda & Tsutsumi [256], it is hypothesised that it is possible for keratinocytes to generate spatially restricted signalling patterns, which they can then transmit to the unmyelinated nerve fibres of the epidermis [256]. While this may not explain the exact localisation of the points and meridians as proposed by TCM, it does however propose a mechanism by which the stimuli by the needle puncture can be transmitted to the unmyelinated nerves present in the skin [257] and hence affect even spatially distant areas (256). In addition, other researchers have linked acupuncture to the concept of neuroimmunology (e.g., [258-262].

One additional research avenue is the study of the location of acupuncture points or meridians, based on the effects of phytochemicals when applied at such locations. The most prominent such efforts concern the application of capsaicin, a phytochemical with numerous beneficial properties [263-267], in acupuncture points which was found to have favourable results [268-270]. Based on the past history of use of certain compounds at acupuncture points [116], other phytochemicals, with demonstrated health-related properties, such as kaempferol [271,272], curcumin [273,274], piperine [275], pinosylvin [276], and a host of natural compounds used in the field of oncology [277], could be used experimentally, to verify or dismiss such claims. Furthermore, it is known that acupuncture can measurably influence certain hormone levels in body fluids [278,279]; therefore, we propose that clinical trials could be designed, especially in cases where hormones or their analogues could be of therapeutical benefits, such as in the case of somatostatin [280, 281].

CONCLUSION

Studies on the detection of TCM meridians and acupuncture points have been ongoing, intermittently, during the last decades, by numerous different research teams, using different experimental setups. Whereas the majority of results is positive, i.e., TCM meridians and acupuncture points can be distinguished from the surrounding skin, due to theirs having different electrical properties, there exist a number of shortcomings in most experimental efforts. To be more precise, the different parameters used in most experiments do not permit an easy comparison of results, while the small sample size oftentimes used raises questions of statistical validity; in a number of cases there is also a lack of control factors. Even though we can conclude that it is possible to detect TCM meridians and acupuncture points using electrical properties, more research efforts are needed in order to standardise the experimental approaches and find a structural or functional basis for their existence.

Conflicts of interest and sources of funding

The authors declare no conflict of interest. No artificial intelligence automatically generated text was inserted in this manuscript, and no image was previously published in another journal or is under consideration for publication elsewhere. This research received no external funding.

Authors’ contribution

Conceptualization, A.P., K.P.; methodology, A.P., K.P., A.I.; validation, A.P., and D.O.C.; formal analysis, A.P.; investigation, A.P., K.P., A.I., L.T., C.M.; resources, C.M.; writing— original draft preparation, , A.P., K.P., A.I., L.T., A.-T.P., C.M., D.O.C.; writing—review and editing, A.P., K.P., A.I., L.T., A.-T.P., D.O.C.; visualization, A.P.; supervision, A.P., K.P., D.O.C.; All authors have read and agreed to the published version of the manuscript.

Ethics approval and consent to participate

Not applicable.

Patient consent for publication

Not applicable.

References

  1. Micunovic I. Origin of Chinese Medicine, Acupuncture & Moxibustion. J Altern Complement Integr Med. 2018;4.
  2. Kim Y-S, Jun H, Chae Y, Park H-J, Kim BH, Chang I-M, et al. The Practice of Korean Medicine: An Overview of Clinical Trials in Acupuncture. Evidence-Based Complementary and Alternative Medicine. 2005;2:345063.
  3. Yin C, Park H-J, Chae Y, Ha E, Park H-K, Lee H-S, et al. Korean acupuncture: the individualized and practical acupuncture. Neurological Research. 2007;29(sup1):10-5.
  4. Ma K-W. The Roots and Development of Chinese Acupuncture: From Prehistory to Early 20Th Century. Acupuncture in Medicine. 1992;10(1_suppl):92-9.
  5. Periferakis A, Periferakis K. On the Dissemination of Acupuncture to Europe. Journal NX – A Multidisciplinary Peer Reviewed Journal. 2020;6(7):201-9.
  6. Periferakis A. [The Appearance of Acupuncture in Europe 1683-1850]. Athens: Akadimia of Ancient Greek and Traditional Chinese Medicine; 2021.
  7. Dubois J. Revisiting the Medical Work of George Soulie De Morant. Chinese Medicine and Culture. 2019;2(2):53-6.
  8. Ezzo J, Berman B, Hadhazy VA, Jadad AR, Lao L, Singh BB. Is acupuncture effective for the treatment of chronic pain? A systematic review. Pain. 2000;86(3):217-25.
  9. Kaptchuk TJ. Acupuncture: Theory, Efficacy, and Practice. Annals of Internal Medicine. 2002;136(5):374-83.
  10. Manheimer E, White A, Berman B, Forys K, Ernst E. Meta-Analysis: Acupuncture for Low Back Pain. Annals of Internal Medicine. 2005;142(8):651-63.
  11. Trinh K, Graham N, Gross A, Goldsmith C, Wang E, Cameron I, et al. Acupuncture for Neck Disorders. Spine. 2007;32(2):236-43.
  12. Yuan J, Purepong N, Kerr DP, Park J, Bradbury I, McDonough S. Effectiveness of Acupuncture for Low Back Pain: A Systematic Review. Spine. 2008;33(23):E887-E900.
  13. VanderPloeg K, Yi X. Acupuncture in Modern Society. Journal of Acupuncture and Meridian Studies. 2009;2(1):26-33.
  14. Mavrommatis CI, Argyra E, Vadalouka A, Vasilakos DG. Acupuncture as an adjunctive therapy to pharmacological treatment in patients with chronic pain due to osteoarthritis of the knee: A 3-armed, randomized, placebo-controlled trial. PAIN. 2012;153(8):1720-6.
  15. Lima FA, Ferreira LE, Pace FH. Acupuncture effectiveness as a complementary therapy in functional dyspepsia patients. Arq Gastroenterol. 2013;50(3):202-7.
  16. Periferakis K, Periferakis A. Treating gout caused by renal insufficiency with acupuncture and moxibustion: a case report. Romanian Journal of Clinical Research. 2023;6(1):21-8.
  17. Karavis MY, Argyra E, Segredos V, Yiallouroy A, Giokas G, Theodosopoulos T. Acupuncture-Induced Haemothorax: A Rare Iatrogenic Complication of Acupuncture. Acupuncture in Medicine. 2015;33(3):237-41.
  18. Haltrecht H. Veterinary acupuncture. Can Vet J. 1999;40(6):401-3.
  19. Habacher G, Pittler MH, Ernst E. Effectiveness of Acupuncture in Veterinary Medicine: Systematic Review. Journal of Veterinary Internal Medicine. 2006;20(3):480-8.
  20. Robinson NG. Veterinary Acupuncture: An Ancient Tradition for Modern Times. Alternative and Complementary Therapies. 2007;13(5):259-65.
  21. Xie H, Sivula NJ, editors. Review of Veterinary Acupuncture Clinical Trials2016.
  22. Yu C, Zhang K, Lu G, Xu J, Xie H, Lui Z, et al. Characteristics of acupuncture meridians and acupoints in animals. Rev Sci Tech. 1994;13(3):927-33.
  23. Ahn AC, Park M, Shaw JR, McManus CA, Kaptchuk TJ, Langevin HM. Electrical impedance of acupuncture meridians: the relevance of subcutaneous collagenous bands. PLoS One. 2010;5(7):e11907.
  24. Hou T, Re Z, Hu B, Li M. Experimental Evidence of a Plant Meridian System II: The Effects of Needle Acupuncture on the Temperature Changes of Soybean (Glycine max). The American journal of Chinese medicine. 1994;22(02):103-10.
  25. Hou T, Luan J, Wang J, Li M. Experimental Evidence of a Plant Meridian System III: The Sound Characteristics of Phylodendron (Alocasia) and Effects of Acupuncture on Those Properties. The American journal of Chinese medicine. 1994;22(03n04):205-14.
  26. Hou T, Dawitor M, Wang J, Li M. Experimental Evidence of a Plant Meridian System I: Bioelectricity and Acupuncture Effects on Electrical Resistance of the Soybean (Glycine max). The American journal of Chinese medicine. 1994;22(01):1-10.
  27. Hou T, Li M. Experimental Evidence of a Plant Meridian System V. Acupuncture Effect on Circumnutation Movements of Shoots of Phaselus vulgaris L. Pole Bean. The American journal of Chinese medicine. 1997;25(03n04):253-61.
  28. Hou T, Li M. Experimental Evidence of a Plant Meridian System IV. The Effects of Acupuncture on Growth and Metabolism of Phaseolus vulgaris L. Beans. The American journal of Chinese medicine. 1997;25(02):135-42.
  29. Yung K-T. A Birdcage Model for the Chinese Meridian System Part V: Applications to Animals and Plants. The American Journal of Chinese Medicine. 2005;33(06):903-12.
  30. Saita HS. Modern scientific medical acupuncture. J Am Osteopath Assoc. 1973;72(7):685-96.
  31. Kroger WS. Hypnotism and acupuncture. Jama. 1972;220(7):1012-3.
  32. Vickland V, Rogers C, Craig A, Tran Y. Electrodermal activity as a possible physiological marker for acupuncture. Complement Ther Clin Pract. 2008;14(2):83-9.
  33. Ahn AC, Martinsen OG. Electrical characterization of acupuncture points: technical issues and challenges. J Altern Complement Med. 2007;13(8):817-24.
  34. Yang X, Xu L, Zhong F, Zhu Y. Data mining-based detection of acupuncture treatment on juvenile myopia. Journal of Traditional Chinese Medicine. 2012;32(3):372-6.
  35. Lee IS, Lee SH, Kim SY, Lee H, Park HJ, Chae Y. Visualization of the Meridian System Based on Biomedical Information about Acupuncture Treatment. Evid Based Complement Alternat Med. 2013;2013:872142.
  36. Jung WM, Lee T, Lee IS, Kim S, Jang H, Kim SY, et al. Spatial Patterns of the Indications of Acupoints Using Data Mining in Classic Medical Text: A Possible Visualization of the Meridian System. Evid Based Complement Alternat Med. 2015;2015:457071.
  37. Stanciu S, Tache IA, Gurzun M, Sorici A, Croitoru A, Cuzino D, et al. Artificial Intelligence in cardiovascular medical imaging. Romanian Journal of Military Medicine. 2020;123(4):310-6.
  38. Yeh HY, Chao CT, Lai YP, Chen HW. Predicting the Associations between Meridians and Chinese Traditional Medicine Using a Cost-Sensitive Graph Convolutional Neural Network. Int J Environ Res Public Health. 2020;17(3).
  39. Gorecki G-P, Tomescu D-R, Pleș L, Panaitescu A-M, Dragosloveanu Ș, Scheau C, et al. Implications of using artificial intelligence in the diagnosis of sepsis/sepsis shock. Germs. 2024;14(1):77.
  40. Burns T, Breathnach SM, Cox N, Griffiths C. Rook’s textbook of dermatology: John Wiley & Sons; 2008.
  41. Kolarsick PA, Kolarsick MA, Goodwin C. Anatomy and physiology of the skin. Journal of the Dermatology Nurses’ Association. 2011;3(4):203-13.
  42. Pappas A. Lipids and skin health. Springer; 2015.
  43. Nicander I, Nyren M, Emtestam L, Ollmar S. Baseline electrical impedance measurements at various skin sites – related to age and sex. Skin Res Technol. 1997;3(4):252-8.
  44. Aberg P, Birgersson U, Elsner P, Mohr P, Ollmar S. Electrical impedance spectroscopy and the diagnostic accuracy for malignant melanoma. Exp Dermatol. 2011;20(8):648-52.
  45. Abe Y, Nishizawa M. Electrical aspects of skin as a pathway to engineering skin devices. APL Bioeng. 2021;5(4):041509.
  46. Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Phys Med Biol. 1996;41(11):2271-93.
  47. Yamamoto T, Yamamoto Y. Electrical properties of the epidermal stratum corneum. Medical and biological engineering. 1976;14(2):151-8.
  48. Miklavčič D, Pavšelj N, Hart FX. Electric Properties of Tissues. Wiley Encyclopedia of Biomedical Engineering2006.
  49. Birgersson U, Birgersson E, Aberg P, Nicander I, Ollmar S. Non-invasive bioimpedance of intact skin: mathematical modeling and experiments. Physiol Meas. 2011;32(1):1-18.
  50. Dean DA, Ramanathan T, Machado D, Sundararajan R. Electrical Impedance Spectroscopy Study of Biological Tissues. J Electrostat. 2008;66(3-4):165-77.
  51. Sasaki K, Wake K, Watanabe S. Measurement of the dielectric properties of the epidermis and dermis at frequencies from 0.5 GHz to 110 GHz. Phys Med Biol. 2014;59(16):4739-47.
  52. Pethig R, Kell DB. The passive electrical properties of biological systems: their significance in physiology, biophysics and biotechnology. Phys Med Biol. 1987;32(8):933-70.
  53. Schwan HP. Electrical Properties of Tissue and Cell Suspensions* *This work was supported in part by grants from the United States Public Health Service, H-1253(c2-4) and in part by the Office of Naval Research, 119–289. In: Lawrence JH, Tobias CA, editors. Advances in Biological and Medical Physics. 5: Elsevier; 1957. p. 147-209.
  54. Daia C, Scheau C, Neagu G, Andone I, Spanu A, Popescu C, et al. Nerve conduction study and electromyography findings in patients recovering from Covid-19 – case report. Int J Infect Dis. 2020.
  55. Gélisse P, Benbadis SR, Crespel A, Tatum WO. Overcoming traps and pitfalls leading to misinterpretation of normal EEG variants and variation of the background activity. J Neurol. 2024;271(7):3869-78.
  56. Soulié de Morant G. Précis de la Vraie Acuponcture Chinoise. Doctrine-Diagnostic-Thérepeutique. Paris: Mercure de France; 1934.
  57. Liangyue D, Yijun G, Shuhui H, Xiaoping J, Yang L, Rufen W, et al. Chinese Acupuncture and Moxibustion. Beijing: Foreign Languages Press; 1987.
  58. Tilikidis A. [The Basic Theory of Traditional Chinese Medicine]. Athens: Akadimia of Ancient Greek and Traditional Chinese Medicine; 1999.
  59. Borbély AA, editor Sleep Regulation: Circadian Rhythm and Homeostasis1982; Berlin, Heidelberg: Springer Berlin Heidelberg.
  60. Scales WE, Vander AJ, Brown MB, Kluger MJ. Human circadian rhythms in temperature, trace metals, and blood variables. Journal of Applied Physiology. 1988;65(4):1840-6.
  61. Smolensky MH, Haus E. Circadian rhythms and clinical medicine with applications to hypertension. American Journal of Hypertension. 2001;14(S6):280S-90S.
  62. Wolff CA, Esser KA. Exercise timing and circadian rhythms. Current Opinion in Physiology. 2019;10:64-9.
  63. Ishihara T, Ferrans VJ, Jones M, Boyce SW, Kawanami O, Roberts WC. Histologic and ultrastructural features of normal human parietal pericardium. The American Journal of Cardiology. 1980;46(5):744-53.
  64. Jaworska-Wilczynska M, Trzaskoma P, Szczepankiewicz AA, Hryniewiecki T. Pericardium: structure and function in health and disease. Folia Histochem Cytobiol. 2016;54(3):121-5.
  65. Wang TH, Wang MH, Shih CC, Lu YH, Zheng HX, Tseng YT, et al. Comparison of physical electrical conductivity and acupuncture de-qi sensation between stainless steel needling and supercritical fluid-treated needling. Biomed J. 2021;44(6 Suppl 2):S267-s74.
  66. Wang T. Dao-qi Needling Technique with Du Mai and Ren Mai. Acupuncture for Brain: Treatment for Neurological and Psychologic Disorders. Cham: Springer International Publishing; 2021. p. 81-98.
  67. Zemtsov A, Shahar J. Skin manifestations of chronic obstructive pulmonary disease. Cutis. 1993;52(2):91-2.
  68. Maclay JD, McAllister DA, Rabinovich R, Haq I, Maxwell S, Hartland S, et al. Systemic elastin degradation in chronic obstructive pulmonary disease. Thorax. 2012;67(7):606-12.
  69. Schwarz MI, Mortenson RL, Colby TV, Waldron JA, Lynch DA, Hutt MP, et al. Pulmonary capillaritis. The association with progressive irreversible airflow limitation and hyperinflation. Am Rev Respir Dis. 1993;148(2):507-11.
  70. Cohen BA, Turcios NL. Pulmonary Manifestations of Skin Disorders in Children. Pediatr Clin North Am. 2021;68(1):261-76.
  71. Nakatani Y. Skin electric resistance and Ryodoraku. J autonomic Nerve. 1956;6(52).
  72. Reichmanis M, Marino AA, Becker RO. Laplace plane analysis of transient impedance between acupuncture points Li-4 and Li-12. IEEE transactions on biomedical engineering. 1977(4):402-5.
  73. Reichmanis M, Marino AA, Becker RO. Laplace plane analysis of impedance between acupuncture points H-3 and H-4. Comp Med East West. 1977;5(3-4):289-95.
  74. Reichmanis M, Marino AA, Becker RO. Laplace plane analysis of impedance on the H meridian. Am J Chin Med. 1979;7(2):188-93.
  75. Ogata H, Matsumoto T, Tsukahara H. Changes in the electrical skin resistance on meridians during gastric surgery under general anesthesia. Am J Chin Med. 1983;11(1-4):123-9.
  76. Ogata H, Matsumoto T, Tsukahara H. Electrical skin resistance changes in meridians during ophthalmic surgery with local anesthesia. Am J Chin Med. 1983;11(1-4):130-6.
  77. Bubnova NA, Petrov SV, Nikitskiĭ IE, Smolina EN, Levitina EI. [Methods for estimating the severity of the status of resuscitated surgical patients]. Vestn Khir Im I I Grek. 1996;155(6):91-3.
  78. Xiang ZZ, Ming XR, Guo XJ, Zhuang YS. Experimental meridian line of stomach and its low impedance nature. Acupunct Electrother Res. 1984;9(3):157-64.
  79. Hu X, Wu B, Huang X, Xu J. Computerized plotting of low skin impedance points. J Tradit Chin Med. 1992;12(4):277-82.
  80. Hu X, Huang X, Xu J, Wu B. [Distribution of low skin impedance points along meridians over the medial side of forearm]. Zhen Ci Yan Jiu. 1993;18(2):94-7.
  81. Huang X, Xu J, Wu B, Hu X. [Observation on the distribution of LSIPs along three yang meridians as well as ren and du meridians]. Zhen Ci Yan Jiu. 1993;18(2):98-103.
  82. Zhang W, Xu R, Zhu Z. The influence of acupuncture on the impedance measured by four electrodes on meridians. Acupunct Electrother Res. 1999;24(3-4):181-8.
  83. Martinsen OG, Grimnes S, Mørkrid L, Hareide M. Line patterns in the mosaic electrical properties of human skin–a cross-correlation study. IEEE Trans Biomed Eng. 2001;48(6):731-4.
  84. Lin YD, Chen BC, Hsu SF, Lin JG. Comments on “Line patterns in the mosaic electric properties of human skin–a cross-correlation study”. IEEE Trans Biomed Eng. 2002;49(3):274.
  85. Johng HM, Cho JH, Shin HS, Soh KS, Koo TH, Choi SY, et al. Frequency dependence of impedances at the acupuncture point Quze (PC3). IEEE Eng Med Biol Mag. 2002;21(2):33-6.
  86. Ahn AC, Wu J, Badger GJ, Hammerschlag R, Langevin HM. Electrical impedance along connective tissue planes associated with acupuncture meridians. BMC Complement Altern Med. 2005;5:10.
  87. Spaulding K, Chamberlin K. The transport of extremely low-frequency electrical signals through an acupuncture meridian compared to nonmeridian tissue. J Altern Complement Med. 2011;17(2):127-32.
  88. Zhu ZX, Yan ZQ, Yu SZ, Zhang RX, Wang JY, Liu YM, et al. Studies on the phenomenon of latent propagated sensation along the channels. I. The discovery of a latent PSC and a preliminary study of its skin electrical conductance. Am J Chin Med. 1981;9(3):216-24.
  89. Li S, Zhao J. Western learning infiltration reflected in the views of meridian in the book Yixue Yuanshi written by WANG Hong-han. Chinese Journal of Basic Medicine in Traditional Chinese Medicine. 2005;15(4):250-2.
  90. Zhu B. [Connotation of channel and its relation with nerve]. Zhonghua Yi Shi Za Zhi. 2004;34(3):153-7.
  91. Zhang W, Zhuang F, Tian Y, Li H. [A simulating study of biophysical features along meridians on a gel model]. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2001;18(3):357-61.
  92. Zhang WB, Wang GJ, Fuxe K. Classic and Modern Meridian Studies: A Review of Low Hydraulic Resistance Channels along Meridians and Their Relevance for Therapeutic Effects in Traditional Chinese Medicine. Evid Based Complement Alternat Med. 2015;2015:410979.
  93. Pawitan JA. Various stem cells in acupuncture meridians and points and their putative roles. Journal of Traditional and Complementary Medicine. 2018;8(4):437-42.
  94. Ogawa M. Differentiation and proliferation of hematopoietic stem cells. 1993.
  95. Wobus AM. Potential of embryonic stem cells. Molecular aspects of medicine. 2001;22(3):149-64.
  96. Sylvester KG, Longaker MT. Stem cells: review and update. Archives of surgery. 2004;139(1):93-9.
  97. Özkurt ZN, Yeǧin ZA, Suyanı E, Akı ŞZ, Acar K, Yaǧcı M, et al. Factors affecting stem cell mobilization for autologous hematopoietic stem cell transplantation. Journal of Clinical Apheresis. 2010;25(5):280-6.
  98. Beck B, Blanpain C. Unravelling cancer stem cell potential. Nature Reviews Cancer. 2013;13(10):727-38.
  99. Hofer HR, Tuan RS. Secreted trophic factors of mesenchymal stem cells support neurovascular and musculoskeletal therapies. Stem Cell Research & Therapy. 2016;7:1-14.
  100. Varghese J, Griffin M, Mosahebi A, Butler P. Systematic review of patient factors affecting adipose stem cell viability and function: implications for regenerative therapy. Stem cell research & therapy. 2017;8(1):1-15.
  101. Tan CY. [Essence of meridians based on neural electric field]. Zhongguo Zhen Jiu. 2010;30(10):835-9.
  102. Jiang Y, Hu H, Li X, Lou J, Zhang Y, He X, et al. Difference in Moxibustion-Induced Microcirculatory Responses between the Heart and Lung Meridians Assessed by Laser Doppler Flowmetry. Evid Based Complement Alternat Med. 2021;2021:6644625.
  103. Ji R, Wang A, Shang H, Chen L, Bao C, Wu L, et al. Herb-partitioned moxibustion upregulated the expression of colonic epithelial tight junction-related proteins in Crohn’s disease model rats. Chin Med. 2016;11:20.
  104. Hu H, Jiang Y, Li X, Lou J, Zhang Y, He X, et al. The microcirculatory characteristics of the heart and lung meridians: Study protocol clinical trial (SPIRIT Compliant). Medicine (Baltimore). 2020;99(14):e19594.
  105. Lin CH, Tan YF, Tseng ST, Chen WC, Kuo CW, Wu CC, et al. Meridian study on the response current affected by acupuncture needling direction. Medicine (Baltimore). 2022;101(35):e30338.
  106. Huang SM, Chien LY, Chang CC, Chen PH, Tai CJ. Abnormal gastroscopy findings were related to lower meridian energy. Evid Based Complement Alternat Med. 2011;2011:878391.
  107. Chang SA, Weng YX, Cheng SC, Chang YJ, Lee TH, Chang CH, et al. Application of Meridian Electrical Conductance in the Setting of Acute Ischemic Stroke: A Cross-Sectional Study. Evid Based Complement Alternat Med. 2019;2019:3098095.
  108. Rezvani M, Alebouyeh MR, Imani F, Entezary SR, Mohseni M. Does changes in the electrical resistance of an acupuncture meridian predict pain intensity following orthopedic surgery? Anesth Pain Med. 2013;2(4):178-81.
  109. Zhang WB, Aukland K, Lund T, Wiig H. Distribution of interstitial fluid pressure and fluid volumes in hind-limb skin of rats: relation to meridians? Clin Physiol. 2000;20(3):242-9.
  110. Liu YW, Kuo CW, Chang TC, Hung YC, Tan YF, Wu CC, et al. Analysis of Meridian Flow Direction by Electrical Stimulation Method. Nanoscale Res Lett. 2022;17(1):64.
  111. Lee F-S, Chiang T-A, Lee J-Y. Correlation Between Ion Contents in Acupuncture Points and Propagated Sensation Along Channels. Acupuncture & Electro-Therapeutics Research. 2022;47(3):329-40.
  112. Brewitt B. Quantitative Analysis of Electrical Skin Conductance in Diagnosis: Historical and Current Views of Bioelectric Medicine. Journal of Naturopathic Medicine. 1996;6:66-75.
  113. Voll R. Twenty years of electroacupuncture diagnosis in Germany: A progress report. Am J Acupunct. 1975;3:7-17.
  114. Seiler H. The points of Weihe – a confirmatory method in classical homeopathy. Allgemeine Homöopathische Zeitung. 2005;250(2):53.
  115. Jayasuriya A. Clinical Homoeopathy : A to Z Homoeopathy Course. First. 1st ed: B. Jain; 1987.
  116. Oliveira A. Electroacupuncture According to Voll: Historical Background and Literature Review. Meridians: The Journal of Acupuncture and Oriental Medicine. 2016;3:5-10.
  117. Werner F, Voll R. Electro Acupuncture Primer. Interpretation of the Acupuncture Rules and the Energy Exchanges and Choice of the Examination Place in Acupuncture acc. to Voll (EAV): Medizinisch Literarische Verlagsgesellschaft; 1979.
  118. Ahn AC, Colbert AP, Anderson BJ, Martinsen OG, Hammerschlag R, Cina S, et al. Electrical properties of acupuncture points and meridians: a systematic review. Bioelectromagnetics. 2008;29(4):245-56.
  119. Frost E, Orkin LR, editors. Localization of acupuncture sites. N.I.H Acupuncture Research Conference; 1973; Maryland, USA.
  120. Kaslow AL. Dragon chasing: a new technique for acupuncture point finding and stimulation. Am J Acupunct. 1975;3(2):157-60.
  121. McCarroll GD. An Investigation of the Existence of Electrically Located Acupuncture Points. Lubbock: Texas Tech University; 1976.
  122. Reichmanis M, Marino AA, Becker RO. Electrical correlates of acupuncture points. IEEE Trans Biomed Eng. 1975;22(6):533-5.
  123. Reichmanis M, Marino AA, Becker RO. D.C. skin conductance variation at acupuncture loci. Am J Chin Med (Gard City N Y). 1976;4(1):69-72.
  124. Hyvärinen J, Karlsson M. Low-resistance skin points that may coincide with acupuncture loci. Med Biol. 1977;55(2):88-94.
  125. McCarroll GD, Rowley BA. An investigation of the existence of electrically located acupuncture points. IEEE Trans Biomed Eng. 1979;26(3):177-81.
  126. Geddes LA, Valentinuzzi ME. Temporal changes in electrode impedance while recording the electrocardiogram with “Dry” electrodes. Annals of Biomedical Engineering. 1973;1(3):356-67.
  127. Poon CS, Choy TT, Koide FT. A reliable method for locating electropermeable points on the skin surface. Am J Chin Med. 1980;8(3):283-9.
  128. Burton CV, Maurer DD. Solvent-activated current passing tape electrode for transcutaneous electrical stimulation of the peripheral nervous system. IEEE Trans Biomed Eng. 1976;23(4):346-7.
  129. Jakoubek B, Rohlícek V. Changes of electrodermal properties in the “acupuncture points” on men and rats. Physiol Bohemoslov. 1982;31(2):143-9.
  130. Falk CX, Birch S, Avants SK, Tsau Y, Margolin A. Preliminary results of a new method for locating auricular acupuncture points. Acupunct Electrother Res. 2000;25(3-4):165-77.
  131. Margolin A, Avants SK, Birch S, Falk CX, Kleber HD. Methodological investigations for a multisite trial of auricular acupuncture for cocaine addiction: a study of active and control auricular zones. J Subst Abuse Treat. 1996;13(6):471-81.
  132. Margolin A, Chang P, Avants SK, Kosten TR. Effects of sham and real auricular needling: implications for trials of acupuncture for cocaine addiction. Am J Chin Med. 1993;21(2):103-11.
  133. Lipton DS, Brewington V, Smith M. Acupuncture for crack-cocaine detoxification: experimental evaluation of efficacy. J Subst Abuse Treat. 1994;11(3):205-15.
  134. Avants SK, Margolin A, Holford TR, Kosten TR. A randomized controlled trial of auricular acupuncture for cocaine dependence. Arch Intern Med. 2000;160(15):2305-12.
  135. Margolin A, Avants SK, Holford TR. Interpreting conflicting findings from clinical trials of auricular acupuncture for cocaine addiction: does treatment context influence outcome? J Altern Complement Med. 2002;8(2):111-21.
  136. Gates S, Smith LA, Foxcroft DR. Auricular acupuncture for cocaine dependence. Cochrane Database Syst Rev. 2006(1):Cd005192.
  137. D’Alberto A. Auricular acupuncture in the treatment of cocaine/crack abuse: a review of the efficacy, the use of the National Acupuncture Detoxification Association protocol, and the selection of sham points. J Altern Complement Med. 2004;10(6):985-1000.
  138. Zhang WB, Jeong DM, Lee YH, Lee MS. Measurement of subcutaneous impedance by four-electrode method at acupoints located with single-power alternative current. Am J Chin Med. 2004;32(5):779-88.
  139. Lee MS, Jeong SY, Lee YH, Jeong DM, Eo YG, Ko SB. Differences in electrical conduction properties between meridians and non-meridians. Am J Chin Med. 2005;33(5):723-8.
  140. Chen K-G. Electrical properties of meridians. IEEE Engineering in Medicine and Biology Magazine. 1996;15(3):58-63.
  141. Pearson S, Colbert AP, McNames J, Baumgartner M, Hammerschlag R. Electrical skin impedance at acupuncture points. J Altern Complement Med. 2007;13(4):409-18.
  142. Kramer S, Zaps D, Wiegele B, Irnich D. Changes in electrical skin resistance at gallbladder 34 (GB34). J Acupunct Meridian Stud. 2008;1(2):91-6.
  143. Kramer S, Winterhalter K, Schober G, Becker U, Wiegele B, Kutz DF, et al. Characteristics of electrical skin resistance at acupuncture points in healthy humans. J Altern Complement Med. 2009;15(5):495-500.
  144. Rezaei S, Khorsand A, Jamali J. Characterisation of Human Skin Impedance at Acupuncture Point Pc4 Ximen and pericardium meridian using the four-electrode method. Acupuncture in Medicine. 2012;30(2):127-31.
  145. Wong YM. Is An Acupuncture Point Identifiable with Skin Electrical Resistance Measurement? Acupuncture in Medicine. 2014;32(2):203-5.
  146. Wei JZ, Shen XY. [Non-linear characteristic of acupoint resistance and its application]. Zhongguo Zhen Jiu. 2023;43(2):171-4.
  147. Mayer-Gindner A, Lek-Uthai A, Abdallah O, Bolz A. Newly explored electrical properties of normal skin and special skin sites. Biomed Tech (Berl). 2004;49(5):117-24.
  148. Lubov JE, Cvammen W, Kemp MG. The Impact of the Circadian Clock on Skin Physiology and Cancer Development. Int J Mol Sci. 2021;22(11).
  149. Camilion JV, Khanna S, Anasseri S, Laney C, Mayrovitz HN. Physiological, Pathological, and Circadian Factors Impacting Skin Hydration. Cureus. 2022;14(8):e27666.
  150. Chen M, Hu XL, Wu ZX. [Observation on changes of oxygen partial pressure in the deep tissues along the large intestine meridian during acupuncture in healthy subjects]. Zhen Ci Yan Jiu. 2010;35(3):213-6.
  151. Becker RO, Reichmanis M, Marino AA, Spadaro JA. Electrophysiological correlates of acupuncture points and meridians. Psychoenergetic Systems. 1976;1(106):195-212.
  152. Croley T. Electrical acupuncture point conductance in the living compared to that in the dead. American Journal of Acupuncture. 1986;14(1):57-60.
  153. Habib AS. Do we really understand what constitutes an acupuncture point? European Journal of Pain. 2012;16(9):1207-8.
  154. Aird M, Coyle M, Cobbin D, Zaslawski C. A study of the comparative accuracy of two methods of locating acupuncture points. Acupuncture in Medicine. 2000;18(1):15-21.
  155. Choi EM, Jiang F, Longhurst JC. Point specificity in acupuncture. Chin Med. 2012;7:4.
  156. Tjen ALSC, Li P, Longhurst JC. Medullary substrate and differential cardiovascular responses during stimulation of specific acupoints. Am J Physiol Regul Integr Comp Physiol. 2004;287(4):R852-62.
  157. Fang JL, Krings T, Weidemann J, Meister IG, Thron A. Functional MRI in healthy subjects during acupuncture: different effects of needle rotation in real and false acupoints. Neuroradiology. 2004;46(5):359-62.
  158. Li P, Ayannusi O, Reid C, Longhurst JC. Inhibitory effect of electroacupuncture (EA) on the pressor response induced by exercise stress. Clin Auton Res. 2004;14(3):182-8.
  159. Zhou W, Fu LW, Tjen ALSC, Li P, Longhurst JC. Afferent mechanisms underlying stimulation modality-related modulation of acupuncture-related cardiovascular responses. J Appl Physiol (1985). 2005;98(3):872-80.
  160. Na BJ, Jahng GH, Park SU, Jung WS, Moon SK, Park JM, et al. An fMRI study of neuronal specificity of an acupoint: electroacupuncture stimulation of Yanglingquan (GB34) and its sham point. Neurosci Lett. 2009;464(1):1-5.
  161. Tao ZL. [The progress of the morphological research on the acupoint]. Zhen Ci Yan Jiu. 1989;14(4):397-402.
  162. Hsiu H, Huang SM, Chao PT, Jan MY, Hsu TL, Wang WK, et al. Microcirculatory characteristics of acupuncture points obtained by laser Doppler flowmetry. Physiol Meas. 2007;28(10):N77-86.
  163. Liang Y, Ma SX, Chen JX. [Effect of nitric oxide on noradrenergic function and skin electric resistance of acupoints and meridians]. Zhen Ci Yan Jiu. 2008;33(3):213-6.
  164. Chen JX, Ma SX. Effects of nitric oxide and noradrenergic function on skin electric resistance of acupoints and meridians. J Altern Complement Med. 2005;11(3):423-31.
  165. Ma SX. [Biochemical physiology of nitric oxide over acupuncture points and meridians: new approach and perspectives]. Zhen Ci Yan Jiu. 2008;33(1):47-8.
  166. Chen JX, Ibe BO, Ma SX. Nitric oxide modulation of norepinephrine production in acupuncture points. Life Sci. 2006;79(23):2157-64.
  167. Ben H, Li L, Gao XY, He W, Rong PJ. [Comparison of NO contents and cutaneous electric conduction quantity at the acupoints and the non-acupoints]. Zhen Ci Yan Jiu. 2009;34(6):383-6, 92.
  168. Ma SX, Mayer E, Lee P, Li XY, Gao EZ. Transcutaneous Electrical Stimulation Increased Nitric Oxide-Cyclic GMP Release Biocaptured Over Skin Surface of Pericardium Meridian and Acupuncture Points in Humans. Acupunct Electrother Res. 2015;40(2):73-86.
  169. Ma SX. Nitric oxide signaling molecules in acupoints: Toward mechanisms of acupuncture. Chin J Integr Med. 2017;23(11):812-5.
  170. Khorsand A, Zhu J, Bahrami-Taghanaki H, Baghani S, Ma L, Rezaei S. Investigation of the Electrical Impedance of Acupuncture Points and Non-Acupuncture Points before and after Acupuncture, using a Four-Electrode Device. Acupuncture in Medicine. 2015;33(3):230-6.
  171. Turner L, Linden W, Marshall C. Electrodermal activity at acupuncture points differentiates patients with current pain from pain-free controls. Appl Psychophysiol Biofeedback. 2013;38(1):71-80.
  172. She YF, Ma LX, Qi CH, Wang YX, Tang L, Li CH, et al. Do changes in electrical skin resistance of acupuncture points reflect menstrual pain? A comparative study in healthy volunteers and primary dysmenorrhea patients. Evid Based Complement Alternat Med. 2014;2014:836026.
  173. Xisheng F, Xiaoyi DU, Lijia P, Xiaodan S, Jun L, Juncha Z, et al. An infrared thermographic analysis of the sensitization acupoints of women with primary dysmenorrhea. J Tradit Chin Med. 2022;42(5):825-32.
  174. Xu YY, Pan LJ, Jia CS, She YF, Li TY, Song XD. [Regularity of body surface resistance at the acupoints of three yin meridians of the foot in reflecting physiological changes of the uterus]. Zhen Ci Yan Jiu. 2020;45(2):157-63.
  175. Wei JZ, Zhang AM, Shen XY, Zhou Y, Zhao L, Zhou Y. [Volt-ampere characteristics of Yuan points of three yin channels of hand in women before, during and after menstruation]. Zhong Xi Yi Jie He Xue Bao. 2006;4(3):260-4.
  176. Silberstein M. The cutaneous intrinsic visceral afferent nervous system: a new model for acupuncture analgesia. J Theor Biol. 2009;261(4):637-42.
  177. Liu LL, Zhao BX, Xie ZH, Fan YP. [Changes of electrical property of the twelve source-points in encephaloma patients before and after surgery]. Zhen Ci Yan Jiu. 2010;35(1):52-5.
  178. Weng CS, Hung YL, Shyu LY, Chang YH. A study of electrical conductance of meridian in the obese during weight reduction. Am J Chin Med. 2004;32(3):417-25.
  179. Yang E, Lu W, Muñoz-Vergara D, Goldfinger E, Kaptchuk TJ, Napadow V, et al. Skin Temperature of Acupoints in Health and Disease: A Systematic Review. J Integr Complement Med. 2022;28(7):552-68.
  180. Yang Z, Zhou M, Wang X, Zhao Y, Chen Z, Lan Y, et al. [Review on skin temperature of acupoints]. Zhongguo Zhen Jiu. 2017;37(1):109-14.
  181. Lin M, Wei H, Zhao L, Zhao J, Cheng K, Deng H, et al. [Review on infrared temperature characteristics of acupoints in recent 10 years]. Zhongguo Zhen Jiu. 2017;37(4):453-6.
  182. Ngai SP, Jones AY, Cheng EK. Lung meridian acupuncture point skin impedance in asthma and description of a mathematical relationship with FEV1. Respir Physiol Neurobiol. 2011;179(2-3):187-91.
  183. Menon GK, Grayson S, Elias PM. Ionic calcium reservoirs in mammalian epidermis: ultrastructural localization by ion-capture cytochemistry. Journal of Investigative Dermatology. 1985;84(6):508-12.
  184. Mauro T, Elias P, Cullander C, Bench G, Sidderas-Haddad E, Feingold K. Acute barrier perturbation abolishes the Ca2+ and K+ gradients in murine epidermis: quantitative measurement using PIXE. Journal of Investigative Dermatology. 1998;111(6):1198-201.
  185. Denda M, Hosoi J, Asida Y. Visual imaging of ion distribution in human epidermis. Biochemical and biophysical research communications. 2000;272(1):134-7.
  186. Warner RR, Myers MC, Taylor DA. Electron probe analysis of human skin: element concentration profiles. Journal of investigative dermatology. 1988;90(1):78-85.
  187. Von Zglinicki T, Lindberg M, Roomans G, Forslind B. Water and ion distribution profiles in human skin. Acta dermato-venereologica. 1993;73(5):340-3.
  188. Moretto P, Surleve-Bazeille J, Licu D, Michelet C, Stoedzel P. Microanalysis of the human skin structure: preliminary results. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 1999;158(1-4):386-92.
  189. Veríssimo A, Alves LC, Filipe P, Silva JN, Silva R, Dolores Ynsa M, et al. Nuclear microscopy: a tool for imaging elemental distribution and percutaneous absorption in vivo. Microscopy research and technique. 2007;70(4):302-9.
  190. Simon M, Barberet P, Moretto P, Bacqueville D, Mavon A, Seznec H. The skin barrier function: a micro-PIXE study. X-Ray Spectrometry: An International Journal. 2009;38(2):132-7.
  191. Kubo A, Ishizaki I, Kubo A, Kawasaki H, Nagao K, Ohashi Y, et al. The stratum corneum comprises three layers with distinct metal-ion barrier properties. Scientific reports. 2013;3(1):1731.
  192. Colbert AP, Spaulding KP, Ahn AC, Cutro JA. Clinical utility of electrodermal activity at acupuncture points: a narrative review. Acupunct Med. 2011;29(4):270-5.
  193. Kwon YB, Kang MS, Han HJ, Beitz AJ, Lee JH. Visceral antinociception produced by bee venom stimulation of the Zhongwan acupuncture point in mice: role of alpha(2) adrenoceptors. Neurosci Lett. 2001;308(2):133-7.
  194. Chen HS, Qu F, He X, Liao D, Kang SM, Lu SJ. The anti-nociceptive effect and the possible mechanism of acupoint stimulation caused by chemical irritants in the bee venom pain model. Brain Res. 2010;1355:61-9.
  195. Kang SY, Kim CY, Roh DH, Yoon SY, Park JH, Lee HJ, et al. Chemical stimulation of the ST36 acupoint reduces both formalin-induced nociceptive behaviors and spinal astrocyte activation via spinal alpha-2 adrenoceptors. Brain Res Bull. 2011;86(5-6):412-21.
  196. Sung SH, Lee G. Bee Venom Acupuncture Effects on Pain and Its Mechanisms: An Updated Review. Toxins (Basel). 2021;13(9).
  197. Liu JP, Zhu JB, Chen SJ, Zhao X. [Study on evaluation index of acupoint transdermal administration–drug delivery coefficient]. Zhongguo Zhen Jiu. 2006;26(7):507-9.
  198. Periferakis K, Periferakis A. Point Detection Anomalies in Bazzoni Auricular Therapy. Journal NX – A Multidisciplinary Peer Reviewed Journal. 2021;7(7):173-7.
  199. Zhang ZJ, Wang XM, McAlonan GM. Neural acupuncture unit: a new concept for interpreting effects and mechanisms of acupuncture. Evid Based Complement Alternat Med. 2012;2012:429412.
  200. Lim S. WHO standard acupuncture point locations. Evidence-Based Complementary and Alternative Medicine. 2010;7(2):167-8.
  201. Cho SJ, Choi KH, Kim MJ, Kwon OS, Kang SY, Seo SY, et al. Biopotential changes of acupuncture points by acupuncture stimulation. Integr Med Res. 2022;11(3):100871.
  202. Matos LC, Machado J, Greten HJ, Monteiro FJ. Changes of skin electrical potential in acupoints from Ren Mai and Du Mai conduits during Qigong practice: Documentation of a clinical phenomenon. J Bodyw Mov Ther. 2019;23(4):713-20.
  203. Kim MS, Seo HD, Sawada K, Ishida M. Study of biosignal response during acupuncture points stimulations. Annu Int Conf IEEE Eng Med Biol Soc. 2008;2008:689-92.
  204. Kim MS, Kim HD, Seo HD, Sawada K, Ishida M. The effect of acupuncture at PC-6 on the electroencephalogram and electrocardiogram. Am J Chin Med. 2008;36(3):481-91.
  205. Pan LJ, Zhang XQ, Liu J, Li TY, Xu YY, Song XD, et al. [Progress of researches on electrical characteristics of meridians and acupoints in recent 10 years]. Zhen Ci Yan Jiu. 2020;45(1):77-82.
  206. Wu B, Hu X, Xu J. [Effect of increase and decrease of measurement voltage on skin impedance]. Zhen Ci Yan Jiu. 1993;18(2):104-7.
  207. She YF, Qi CH, Zhu J. [History and progress of study on electrical properties of acupoints at home and abroad]. Zhongguo Zhen Jiu. 2010;30(12):1047-50.
  208. Prokhorov EF, Prokhorova TE, González-Hernández J, Kovalenko YA, Llamas F, Moctezuma S, et al. In vivo dc and ac measurements at acupuncture points in healthy and unhealthy people. Complement Ther Med. 2006;14(1):31-8.
  209. Luo L, Zhou Y, Yang M, Zheng H, Liang F. [Confounding factors in research for characteristics of acupoint electrical impedance]. Zhongguo Zhen Jiu. 2018;38(1):83-6.
  210. Godson DR, Wardle JL. Accuracy and Precision in Acupuncture Point Location: A Critical Systematic Review. Journal of Acupuncture and Meridian Studies. 2019;12(2):52-66.
  211. Andrade C. Sample Size and its Importance in Research. Indian J Psychol Med. 2020;42(1):102-3.
  212. Leppink J, Winston K, O’Sullivan P. Statistical significance does not imply a real effect. Perspectives on Medical Education. 2016;5(2):122-4.
  213. Kwok G, Cohen M, Cosic I. Mapping acupuncture points using multi channel device. Australas Phys Eng Sci Med. 1998;21(2):68-72.
  214. Wiegele B, Schober G, Kuder J, Kolb FP, Irnich D. [A new sensor technique for measurements of electrical potential profiles of human skin at acupuncture points]. Forsch Komplementmed. 2006;13(4):227-32.
  215. Lee YH, Jeong DM, Jeong SY, Lee MS. Development of a system and improvement of the stimulus pattern to discriminate the acupuncture point and meridians. Int J Neurosci. 2005;115(7):989-1002.
  216. Fico T, Duchon F, Dubravsky J. Hardware and software realization of EDSD for acupuncture research and practice. IEEE J Biomed Health Inform. 2014;18(4):1207-13.
  217. Lanzanò L, Grasso R, Gulino M, Bellia P, Falciglia F, Scordino A, et al. Corresponding measurements of delayed luminescence and impedance spectroscopy on acupuncture points. Indian J Exp Biol. 2008;46(5):364-70.
  218. Moldovan C. Biophysics behavior of acupuncture points irradiated with low energy lasers. Rom J Intern Med. 2007;45(3):281-5.
  219. Litscher G, Wang L, Gao XY, Gaischek I. Electrodermal mapping: A new technology. World J Methodol. 2011;1(1):22-6.
  220. Turner L, Linden W, Talbot Ellis A, Millman R. Measurement reliability for acupoint activity determined with the prognos ohmmeter. Appl Psychophysiol Biofeedback. 2010;35(3):251-6.
  221. Yang H, Li J, Luo L, Ye J, Xiao Q, Wang X, et al. [Acupoint electrosensitivity and regularity based on bibliometric]. Zhongguo Zhen Jiu. 2018;38(6):617-21.
  222. Zhang K, Ding S-s, Gong Y-n, Zhao X, Li K. Initiation mechanisms of acupuncture effect: a literature review of basic studies. Journal of Acupuncture and Tuina Science. 2020;18(1):75-82.
  223. Dawidowicz J, Szotek S, Matysiak N, Mielańczyk Ł, Maksymowicz K. Electron microscopy of human fascia lata: focus on telocytes. J Cell Mol Med. 2015;19(10):2500-6.
  224. Popescu LM, Faussone-Pellegrini MS. TELOCYTES – a case of serendipity: the winding way from Interstitial Cells of Cajal (ICC), via Interstitial Cajal-Like Cells (ICLC) to TELOCYTES. J Cell Mol Med. 2010;14(4):729-40.
  225. Suciu L, Popescu LM, Gherghiceanu M, Regalia T, Nicolescu MI, Hinescu ME, et al. Telocytes in Human Term Placenta: Morphology and Phenotype. Cells Tissues Organs. 2010;192(5):325-39.
  226. Hinescu ME, Gherghiceanu M, Suciu L, Popescu LM. Telocytes in pleura: two- and three-dimensional imaging by transmission electron microscopy. Cell and Tissue Research. 2011;343(2):389-97.
  227. Popescu LM, Manole E, Şerboiu CS, Manole CG, Suciu LC, Gherghiceanu M, et al. Identification of telocytes in skeletal muscle interstitium: implication for muscle regeneration. Journal of Cellular and Molecular Medicine. 2011;15(6):1379-92.
  228. Popescu LM, Gherghiceanu M, Suciu LC, Manole CG, Hinescu ME. Telocytes and putative stem cells in the lungs: electron microscopy, electron tomography and laser scanning microscopy. Cell and Tissue Research. 2011;345(3):391-403.
  229. Suciu LC, Popescu BO, Kostin S, Popescu LM. Platelet-derived growth factor receptor-β-positive telocytes in skeletal muscle interstitium. Journal of Cellular and Molecular Medicine. 2012;16(4):701-7.
  230. Popescu BO, Gherghiceanu M, Kostin S, Ceafalan L, Popescu LM. Telocytes in meninges and choroid plexus. Neuroscience Letters. 2012;516(2):265-9.
  231. Cretoiu SM, Radu BM, Banciu A, Banciu DD, Cretoiu D, Ceafalan LC, et al. Isolated human uterine telocytes: immunocytochemistry and electrophysiology of T-type calcium channels. Histochemistry and Cell Biology. 2015;143(1):83-94.
  232. Manole CG, Gherghiceanu M, Ceafalan LC, Hinescu ME. Dermal Telocytes: A Different Viewpoint of Skin Repairing and Regeneration. Cells. 2022;11(23):3903.
  233. Felisbino SL, Sanches BDA, Delella FK, Scarano WR, Dos Santos FCA, Vilamaior PSL, et al. Prostate telocytes change their phenotype in response to castration or testosterone replacement. Sci Rep. 2019;9(1):3761.
  234. Suciu L, Nicolescu MI, Popescu LM. Cardiac telocytes: serial dynamic images in cell culture. Journal of Cellular and Molecular Medicine. 2010;14(11):2687-92.
  235. Aleksandrovych V, Pasternak A, Basta P, Sajewicz M, Walocha JA, Gil K. Telocytes: facts, speculations and myths (Review article). Folia Med Cracov. 2017;57(1):5-22.
  236. Stzepourginski I, Nigro G, Jacob JM, Dulauroy S, Sansonetti PJ, Eberl G, et al. CD34+ mesenchymal cells are a major component of the intestinal stem cells niche at homeostasis and after injury. Proc Natl Acad Sci U S A. 2017;114(4):E506-e13.
  237. Shoshkes-Carmel M, Wang YJ, Wangensteen KJ, Tóth B, Kondo A, Massasa EE, et al. Subepithelial telocytes are an important source of Wnts that supports intestinal crypts. Nature. 2018;557(7704):242-6.
  238. Varga I, Polák Š, Kyselovič J, Kachlík D, Danišovič Ľ, Klein M. Recently Discovered Interstitial Cell Population of Telocytes: Distinguishing Facts from Fiction Regarding Their Role in the Pathogenesis of Diverse Diseases Called “Telocytopathies”. Medicina (Kaunas). 2019;55(2).
  239. Yonghong S, Ruizhi W, Yue Z, Xuebing B, Tarique I, Chunhua L, et al. Telocytes in Different Organs of Vertebrates: Potential Essence Cells of the Meridian in Chinese Traditional Medicine. Microscopy and Microanalysis. 2020;26(3):575-88.
  240. Langevin HM, Yandow JA. Relationship of acupuncture points and meridians to connective tissue planes. Anat Rec. 2002;269(6):257-65.
  241. Hua P, Lü H, Yuan L, Tang L. [Four main schools of thought and analysis in studies of channels and collaterals]. Zhongguo Zhen Jiu. 2006;26(6):407-13.
  242. Mingfu L, Xiaotong D, Xiaojing S, Jin J, Jinling Z, Ying H. Study on the dynamic compound structure composed of mast cells, blood vessels, and nerves in rat acupoint. Evid Based Complement Alternat Med. 2013;2013:160651.
  243. Stefanov M, Potroz M, Kim J, Lim J, Cha R, Nam M-H. The Primo Vascular System as a New Anatomical System. Journal of Acupuncture and Meridian Studies. 2013;6(6):331-8.
  244. Li N-c, Li M-y, Chen B, Guo Y. A New Perspective of Acupuncture: The Interaction among Three Networks Leads to Neutralization. Evidence-Based Complementary and Alternative Medicine. 2019;2019:2326867.
  245. Ceafalan L, Gherghiceanu M, Popescu LM, Simionescu O. Telocytes in human skin–are they involved in skin regeneration? J Cell Mol Med. 2012;16(7):1405-20.
  246. Bai X, Mei L, Shi Y, Huang H, Guo Y, Liang C, et al. The Cellular Mechanism of Acupuncture for Ulcerative Colitis based on the Communication of Telocytes. Microscopy and Microanalysis. 2023.
  247. Piipponen M, Li D, Landén NX. The Immune Functions of Keratinocytes in Skin Wound Healing. Int J Mol Sci. 2020;21(22).
  248. Denda M, Fuziwara S, Inoue K, Denda S, Akamatsu H, Tomitaka A, et al. Immunoreactivity of VR1 on epidermal keratinocyte of human skin. Biochemical and biophysical research communications. 2001;285(5):1250-2.
  249. Dhaka A, Viswanath V, Patapoutian A. Trp ion channels and temperature sensation. Annu Rev Neurosci. 2006;29:135-61.
  250. Denda M, Sokabe T, Fukumi-Tominaga T, Tominaga M. Effects of skin surface temperature on epidermal permeability barrier homeostasis. Journal of Investigative Dermatology. 2007;127(3):654-9.
  251. Tsutsumi M, Denda S, Ikeyama K, Goto M, Denda M. Exposure to low temperature induces elevation of intracellular calcium in cultured human keratinocytes. The Journal of investigative dermatology. 2010;130(7):1945-8.
  252. Denda M, Tsutsumi M, Denda S. Topical application of TRPM8 agonists accelerates skin permeability barrier recovery and reduces epidermal proliferation induced by barrier insult: role of cold-sensitive TRP receptors in epidermal permeability barrier homoeostasis. Experimental dermatology. 2010;19(9):791-5.
  253. Tsutsumi M, Kumamoto J, Denda M. Intracellular calcium response to high temperature is similar in undifferentiated and differentiated cultured human keratinocytes. Experimental dermatology. 2011;20(10):839-40.
  254. Inoue K, Denda M, Tozaki H, Fujishita K, Koizumi S, Inoue K. Characterization of multiple P2X receptors in cultured normal human epidermal keratinocytes. Journal of investigative dermatology. 2005;124(4):756-63.
  255. Denda M, Fujiwara S, Hibino T. Expression of voltage-gated calcium channel subunit α1C in epidermal keratinocytes and effects of agonist and antagonists of the channel on skin barrier homeostasis. Experimental dermatology. 2006;15(6):455-60.
  256. Denda M, Tsutsumi M. Possible Role of Epidermal Keratinocytes in the Construction of Acupuncture Meridians. Journal of Acupuncture and Meridian Studies. 2014;7(2):92-4.
  257. Kennedy WR, Wendelschafer-Crabb G. The innervation of human epidermis. Journal of the neurological sciences. 1993;115(2):184-90.
  258. Yi L, Hui F, Yali M, Jingfang G, Hongjing M, Mingfen S, et al. Effect of soothing-liver and nourishing-heart acupuncture on early selective serotonin reuptake inhibitor treatment onset for depressive disorder and related indicators of neuroimmunology: a randomized controlled clinical trial. Journal of Traditional Chinese Medicine. 2015;35(5):507-13.
  259. Liu Y, Feng H, Mo Y-L, Liu W-J, Song M-F, Wang S-D, et al. Effect of acupuncture on early onset of SSRIs treating depressive disorder and related indicators of neuroimmunology. Zhongguo Zhong xi yi jie he za zhi Zhongguo Zhongxiyi Jiehe Zazhi= Chinese Journal of Integrated Traditional and Western Medicine. 2015;35(3):299-303.
  260. Su Y-S, Li Y-M, Jing X-H, Wang Y-Q, Han S-P, Pan W-X, et al. The significance of” A neuroanatomical basis for electroacupuncture to drive the vagal-adrenal axis” published in Nature for acupuncture research. Zhen ci yan jiu= Acupuncture Research. 2022;47(1):1-6.
  261. Li Y-M. The path of translational medicine for neuroimmunological anti-inflammation and its enlightenment to acupuncture. Zhen ci yan jiu= Acupuncture Research. 2023;48(1):21-7.
  262. Ulloa L. Bioelectronic neuro-immunology: Neuronal networks for sympathetic-splenic and vagal-adrenal control. Neuron. 2023;111(1):10-4.
  263. Popescu GDA, Scheau C, Badarau IA, Dumitrache M-D, Caruntu A, Scheau A-E, et al. The Effects of Capsaicin on Gastrointestinal Cancers. Molecules. 2021;26(1):94.
  264. Dumitrache MD, Jieanu AS, Scheau C, Badarau IA, Popescu GDA, Caruntu A, et al. Comparative effects of capsaicin in chronic obstructive pulmonary disease and asthma (Review). Exp Ther Med. 2021;22(3):917.
  265. Scheau C, Ilie Ghita M, Grigore O, Mihailescu A, Caruntu A, Mihai L, et al. Modulation of capsaicin-induced neurogenic vasodilation by acute psychological stress. Farmacia. 2021;69(4).
  266. Periferakis A-T, Periferakis A, Periferakis K, Caruntu A, Badarau IA, Savulescu-Fiedler I, et al. Antimicrobial Properties of Capsaicin: Available Data and Future Research Perspectives. Nutrients. 2023;15(19):4097.
  267. Petran EM, Periferakis A, Troumpata L, Periferakis A-T, Scheau A-E, Badarau IA, et al. Capsaicin: Emerging Pharmacological and Therapeutic Insights. Current Issues in Molecular Biology. 2024;46(8):7895-943.
  268. Kim KS, Koo MS, Jeon JW, Park HS, Seung IS. Capsicum plaster at the korean hand acupuncture point reduces postoperative nausea and vomiting after abdominal hysterectomy. Anesth Analg. 2002;95(4):1103-7, table of contents.
  269. Agarwal A, Dhiraaj S, Tandon M, Singh PK, Singh U, Pawar S. Evaluation of capsaicin ointment at the Korean hand acupressure point K-D2 for prevention of postoperative nausea and vomiting. Anaesthesia. 2005;60(12):1185-8.
  270. Kim KS, Nam YM. The analgesic effects of capsicum plaster at the Zusanli point after abdominal hysterectomy. Anesth Analg. 2006;103(3):709-13.
  271. Periferakis A, Periferakis K, Badarau IA, Petran EM, Popa DC, Caruntu A, et al. Kaempferol: Antimicrobial Properties, Sources, Clinical, and Traditional Applications. Int J Mol Sci. 2022;23(23):15054.
  272. Periferakis A, Periferakis A-T, Troumpata L, Periferakis K, Scheau A-E, Savulescu-Fiedler I, et al. Kaempferol: A Review of Current Evidence of Its Antiviral Potential. International Journal of Molecular Sciences. 2023;24(22):16299.
  273. Sharma RA, Gescher AJ, Steward WP. Curcumin: the story so far. European journal of cancer. 2005;41(13):1955-68.
  274. Pulido-Moran M, Moreno-Fernandez J, Ramirez-Tortosa C, Ramirez-Tortosa M. Curcumin and Health. Molecules. 2016;21(3):264.
  275. Periferakis A, Troumpata L, Periferakis K, Adalis G, Periferakis A, Georgatos-Garcia S, et al. Traditional Ethnomedical and Ethnobotanical Applications and Uses of Piper Nigrum. RJ Mil Med. 2025;128(4):286-303.
  276. Periferakis A, Periferakis A-T, Troumpata L, Periferakis K, Georgatos-Garcia S, Touriki G, et al. Pinosylvin: A Multifunctional Stilbenoid with Antimicrobial, Antioxidant, and Anti-Inflammatory Potential. Curr Issues Mol Biol. 2025;47(3):204.
  277. Scheau C, Mihai LG, Bădărău IA, Caruntu C. Emerging applications of some important natural compounds in the field of oncology. Farmacia. 2020;68(6):992-8.
  278. Akimoto T, Nakahori C, Aizawa K, Kimura F, Fukubayashi T, Kono I. Acupuncture and responses of immunologic and endocrine markers during competition. Medicine & Science in Sports & Exercise. 2003;35(8):1296-302.
  279. Zheng J-y, Zhu J, Wang Y, Tian Z-z. Effects of acupuncture on hypothalamic–pituitary–adrenal axis: Current status and future perspectives. Journal of Integrative Medicine. 2024;22(4):445-58.
  280. Periferakis A, Tsigas G, Periferakis A-T, Badarau IA, Scheau A-E, Tampa M, et al. Antitumoral and Anti-inflammatory Roles of Somatostatin and Its Analogs in Hepatocellular Carcinoma. Analytical Cellular Pathology. 2021;2021(1):1840069.
  281. Periferakis A, Tsigas G, Periferakis A-T, Tone CM, Hemes DA, Periferakis K, et al. Agonists, Antagonists and Receptors of Somatostatin: Pathophysiological and Therapeutical Implications in Neoplasias. Curr Issues Mol Biol. 2024;46(9):9721-59.

Detection of Acupuncture Points and Meridians Based on their Electrical Properties: Current Evidence and Future Research Perspectives

Cite this article

APA Style

Periferakis, A., Periferakis, K., Iftime, A., Troumpata, L., Periferakis, A.-T., Maier, C., & Costache, D.O. (2025). Detection of acupuncture points and meridians based on their electrical properties: current evidence and future research perspectives. Romanian Journal of Military Medicine, 128(5), 378-400. https://doi.org/10.55453/rjmm.2025.128.5.2

Vancouver Style

Periferakis A, Periferakis K, Iftime A, Troumpata L, Periferakis AT, Maier C, et al. Detection of Acupuncture Points and Meridians Based on their Electrical Properties: Current Evidence and Future Research Perspectives. Rom J Mil Med. 2025;128(5):378-400. doi:10.55453/rjmm.2025.128.5.2.

Harvard Style

Periferakis, A., Periferakis, K., Iftime, A., Troumpata, L., Periferakis, A.-T., Maier, C. & Costache, D.O. 2025, 'Detection of Acupuncture Points and Meridians Based on their Electrical Properties: Current Evidence and Future Research Perspectives', Romanian Journal of Military Medicine, vol. 128, no. 5, pp. 378-400, doi:10.55453/rjmm.2025.128.5.2.